Summary

PRSL240265
Solar
Returned for Correction
UHL, WILLIAM T & JODIE H (JT)
New
Rooftop construction of 3.2kW PV+storage solar on Ag/Utility pole barn. Pole barn is AG Exempt, see attached drawings for structural. System will not be connected to Electric Grid.
04/11/2024
10/08/2024

Locations

Submittals

1 Permit Application Submittal 04/11/2024      Status: Returned for Correction

Review Type Outcome Est. Completion Date Completed
Fire Code Review Approved 05/06/2024 05/17/2024
Trevor Guire ((970) 276-3511)   Send Email
Approved [tguire @ 05/17/2024 1:49 PM]
Electrical Review Approved 05/06/2024 05/06/2024
Tom Cook ((970) 870-5339)   Send Email
Final approval subject to field inspection
Building Code Review Failed 05/06/2024 05/01/2024
Ted Allen ((970) 870-5329)   Send Email
Miscellaneous
Outstanding
05/01/2024


Rooftop-mounted photovoltaic panel systems shall be designed to structurally support the system and withstand applicable gravity loads in accordance with local requirements. Located in this area results in a recommended ground snow load of approximately 90 psf, the wind speed is 115 mph "Ult." and seismic zone "C". Design loads used in the design shown on Sheet PV-3.1 appear inadequate and both requires revisions.
See Document Markups
Outstanding
05/01/2024


Solar panels supported by two IronRidge rails and connected to the roof structure below with quickmount brackets to metal roof, with brackets at 4’-0” on center maximum spacing, the brackets will likely miss the structural frames shown on the framing plan in the direction as ribs are not all spaced at 48”. The specifications for these materials shall all be backed up by Ironridge span charts and reviewed whether brackets will be located over timber frames (shown as ribs) or if rafters have been added for the metal roof show specifications as neither are shown on post timberframe plans.
Miscellaneous
Outstanding
05/01/2024


As part of the solar permitting process we typically review the structural loads of existing roof members. Design loads used in the design including soil bearing pressure based on the approved geotechnical report used in the design shall be stated on the complete structural plans with general notes and material specifications for post timber frames. Otherwise, Routt County Regional Building Department (RCRBD) typically requests a review and signed letter from design professional or EOR to be included with the submittal.
Planning Review Failed 05/06/2024 04/29/2024
Michael Fitz ((970) 879-2704)   Send Email
Miscellaneous
Outstanding
04/29/2024


Please correct site plan to match ground conditions. The North arrow implies that the "driveway" is actually County Road 68. However County Road 68 is listed at the bottom of the site plan, which would imply it runs east-west (it does not). If the "driveway" is indeed County Road 68, then one of the 3 cabins does not meet the 80' road centerline setbacks. The shape of the parcel is also confusing, being wider than it is tall, and more closely matches the shape of parcel 939013002 to the north.
Solar proposed on barn roof. Unable to properly review, as site plan does not appear to match ground conditions. See Corrections for details.

2 Permit Application Submittal 05/17/2024      Status: Pending


Fees

Paid Fees Amount Paid Owing Date Paid
Residential Solar Plan Review Fee - Routt $106.03 $106.03 Paid 04/11/2024
Routt County Planning Dept Plan Review Fee $75.00 $75.00 Paid 04/11/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.