Summary

PRRN240950
Alteration
Canceled
TWO CREEKS RIDGE LLC
Alteration
We are replacing the siding, windows and roof on an existing metal building (built @1982) in the first phase of the project. Same time we are replacing all the insulation to bring up to code R49+ roof and R21+ walls. Future phases will include renovating the office spaces, bathrooms, locker rooms, break room / kitchen and mechanical room located in the east end section of the building. More details below. We (Two Creeks Ridge LLC) bought the building from Peabody / Sage Creel Lands in 2019. Same time as we bought the building and its parcel (40 acres), we also bought 307 acres in agriculture from Peabody / Sage Creek. We plan to improve the building's condition in several stages over what is expected to be 1.5 to 2 years. We are doing the build on the project ourselves as owners, but we will be using some contractors for skilled trades as needed. The equipment on site (Genie and Kubota) are my own. The main phases of the project are replacing the (1)(a) metal skin and (1)(b) its windows same time; and (2) replacing the roof. At this point, we want to be dried-in by end September. We are brining the roof insulation up to code with at 49+ (Atlas panels are on-site). After dried-in, the next phase in September or October was to insulate the new wall panels at R21+ with closed cell foam. After dried-in and insulated, we will be supplementing the building's heat system. It has operating electric heaters but we will be adding a gas boiler to heat the east end of the building via radiant heat. Will be engaging with HVAC specialist on this scope but are some months away. We have had well water, septic and electrical. The building has had propane heat before and we have propane tank on site that is code compliant, but have purposefully not installed a regulator as waiting for the boiler install by HVAC specialist to pull permit, do the work and connect up propane service. The rest of the work scope are refurbing our bathrooms, locker room and offices spaces on the east end of the building. This building is not for public use / not for commercial use. We will continue to use it same as we have been to support our plans for the agricultural land.
08/08/2024
02/04/2025

Locations

Property
268400018

Submittals

1 Permit Application Submittal 08/08/2024      Status: Pending
Review Type Outcome Est. Completion Date Completed
There are no reviews associated with this application, or you are not authorized to view them.

Fees

Paid Fees Amount Paid Owing Date Paid
None $0.00 $0.00 $0.00
Outstanding Fees Amount Paid Owing Date Paid
Oak Creek Fire Permit Fee $110.00 $0.00 Not payable Not Paid


$0.00

Inspections

There are no inspections for this permit application, or you are not authorized to view them.

Conditions

There are no conditions for this permit application, or you are not authorized to view them.

Related Permit & Planning Applications

There are no related items for this permit application.

Documents & Images

Date Uploaded File Type Name
09/23/2024 Letter Incomplete Application Notice (Generate/Send Incomplete Application Notice)