Summary

PRSF220803
New Single Family Dwelling
Permit(s) Issued
ASPENWOOD HOMES LLC
New
R-3 - Residential, one- and two-family
2654 Sq. Ft. Single Family Dwelling with 528 Sq. Ft. Attached Garage.
06/21/2022
07/11/2022
07/11/2025

Locations

Submittals

1 Permit Application Submittal 06/21/2022      Status: Returned for Correction

Review Type Outcome Est. Completion Date Completed
Public Works Review Approved 07/08/2022 07/07/2022
Tony Brown ((970) 870-5344)   Send Email
GIS Land Development Review Approved 07/08/2022 07/01/2022
Jason Blair ((970) 870-5465)   Send Email
Building Code Review Failed 07/08/2022 06/29/2022
Ted Allen ((970) 870-5329)   Send Email
Miscellaneous
Carried Forward
07/11/2022


All construction shall comply with the 2018 local code amendments as shown on approved plans. Energy provisions from the International Energy Conservation Code—Residential Provisions applicable to residential buildings which fall under the scope of this code are required to be shown in the plans. A building section through the representative wall and floors as required to show the thermal envelope shall be submitted (building and section cuts on the plans for A/8 and B/8 appear missing from submittal). All information shall be using Zone 7, Dry. Details shall include, but are not limited to, as applicable: 1. Insulation materials and their R-values (include per inch) is not provided for the garage frost wall. where a minimum of R-10 insulation is required from the top of the slab downward 48" (without gaps) if garage were heated. If not, then the separation wall shall be insulated and shown on plans. 2. Fenestration U-factors windows and doors less than or equal to 0.30 will be required. This will apply for all glazing in windows and doors installed on-site. The builder shall leave the National Fenestration Rating Council (NFRC) labels on all windows and doors with glazing at time of rough inspections so inspectors can verify the glazing requirements. 3. Area-weighted U-factor calculations (if applicable). 4. Air sealing details. Detail B/8 is cut through what appears as a fireplace. Please show details of fireplace to include type of fuel, damper or tight fitting door and outside combustible air as applicable for code compliance. 5. The dwelling unit shall be tested and verified as having an air leakage rate of not exceeding three air changes per hour.
Miscellaneous
Carried Forward
07/11/2022


The adopted codes in Routt County are the 2018 ICC model codes to include APPENDIX F RADON CONTROL METHODS. Required on all New Single Family home, Passive Radon Gas Controls are required. Please show the components of a passive submembrane depressurization system that shall be installed during construction.
Miscellaneous
Carried Forward
07/11/2022


Architectural building sections and details shall include the following information: A. Interior wall and ceiling finishes. (1/2” drywall is required where foam insulation is used) B. The plans show egress location coinciding with the proposed bedroom. For proposed bedrooms indicate the sill height, clear opening width, and clear opening height for the required emergency escape window. Glass area in habitable rooms shall not be less than 8% of floor area served. One-half of this area must be available for unobstructed ventilation with screens included. Artificial lights and/or mechanical ventilation (see ventilation section) may be used as an alternative Glazing in doors intended for human passage, patio doors, windows within 24" of a door, and shower and bathtub enclosure walls, panels or doors, shall be fully tempered.
Fire Code Review Approved 07/08/2022 06/29/2022
Brady Glauthier ((970) 736-8104)   Send Email
Environmental Health Review Approved 07/08/2022 06/23/2022
Amanda Williams ((970) 870-5588)   Send Email
Not applicable location is under MC water district
External Agencies Review Approved 07/08/2022 06/23/2022
Malea Michael-Ferrier ((970) 870-5334)   Send Email
YVEA - inspections@yvea.com Meter to be located as described by YVEA. They shall not be enclosed, covered or concealed. Violation shall result in termination of service. This approval addresses only the meter and service location. Morrison Creek Water and Sanitation All fees are paid with the MCMWSD. Approved. 6/22/22 GDR.
Planning Review Approved 07/08/2022 06/22/2022
Michael Fitz ((970) 879-2704)   Send Email
Planning approves for FOUNDATION ONLY per Chris Brookshire. Applicant understands that they are proceeding at their own risk, and vertical construction per these plans is not approved until Planning permit PL20220040 is completed and closed. Full review - setbacks (building envelope), height OK. Skyline OK, Geology OK, Waterbodies OK, Floodplain OK, Fire risk mapped as Low.

2 Permit Application Submittal 07/07/2022      Status: Pending

Review Type Outcome Est. Completion Date Completed
Building Code Review Approved 07/13/2022 07/11/2022
Ted Allen ((970) 870-5329)   Send Email
Miscellaneous
Outstanding
07/11/2022


All construction shall comply with the 2018 local code amendments as shown on approved plans. Energy provisions from the International Energy Conservation Code—Residential Provisions applicable to residential buildings which fall under the scope of this code are required to be shown in the plans. A building section through the representative wall and floors as required to show the thermal envelope shall be submitted (building and section cuts on the plans for A/8 and B/8 appear missing from submittal). All information shall be using Zone 7, Dry. Details shall include, but are not limited to, as applicable: 1. Insulation materials and their R-values (include per inch) is not provided for the garage frost wall. where a minimum of R-10 insulation is required from the top of the slab downward 48" (without gaps) if garage were heated. If not, then the separation wall shall be insulated and shown on plans. 2. Fenestration U-factors windows and doors less than or equal to 0.30 will be required. This will apply for all glazing in windows and doors installed on-site. The builder shall leave the National Fenestration Rating Council (NFRC) labels on all windows and doors with glazing at time of rough inspections so inspectors can verify the glazing requirements. 3. Area-weighted U-factor calculations (if applicable). 4. Air sealing details. Detail B/8 is cut through what appears as a fireplace. Please show details of fireplace to include type of fuel, damper or tight fitting door and outside combustible air as applicable for code compliance. 5. The dwelling unit shall be tested and verified as having an air leakage rate of not exceeding three air changes per hour.
Miscellaneous
Outstanding
07/11/2022


The adopted codes in Routt County are the 2018 ICC model codes to include APPENDIX F RADON CONTROL METHODS. Required on all New Single Family home, Passive Radon Gas Controls are required. Please show the components of a passive submembrane depressurization system that shall be installed during construction.
Miscellaneous
Outstanding
07/11/2022


Architectural building sections and details shall include the following information: A. Interior wall and ceiling finishes. (1/2” drywall is required where foam insulation is used) B. The plans show egress location coinciding with the proposed bedroom. For proposed bedrooms indicate the sill height, clear opening width, and clear opening height for the required emergency escape window. Glass area in habitable rooms shall not be less than 8% of floor area served. One-half of this area must be available for unobstructed ventilation with screens included. Artificial lights and/or mechanical ventilation (see ventilation section) may be used as an alternative Glazing in doors intended for human passage, patio doors, windows within 24" of a door, and shower and bathtub enclosure walls, panels or doors, shall be fully tempered.

Fees

Paid Fees Amount Paid Owing Date Paid
Routt County Planning Dept Plan Review Fee $75.00 $75.00 Paid 06/21/2022
Routt County Use Tax Fee $2,500.00 $2,500.00 Paid 07/10/2022
Building Permit Fee $2,910.38 $2,910.38 Paid 07/10/2022
Plan Review Fee $1,891.75 $1,891.75 Paid 06/21/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Grading Inspection Pending
Mike Mordi   Send Email
Final Grading Inspection Pending
Tony Brown ((970) 870-5344)   Send Email
Building Final Inspection Pending
Framing Inspection Pending
Foundation Inspection Pending
Structural Inspection Pending
Footing Inspection Partial Pass 8/10/2022 (PM) 8/12/2022 08/12/2022
Jeff Yeiser ((970) 870-5371)   Send Email
Miscellaneous
Outstanding
08/12/2022
Add void forms, home owner is worried that they will deteriorate before concrete is poured. Re-inspect

Footing Inspection Passed 8/22/2022 8/22/2022 08/22/2022
Jeff Yeiser ((970) 870-5371)   Send Email
Foundation Inspection Partial Pass 9/6/2022 9/6/2022 09/06/2022
Jeff Yeiser ((970) 870-5371)   Send Email
Foundation Drain Inspection Passed 9/29/2022 9/29/2022 09/29/2022
Jeff Yeiser ((970) 870-5371)   Send Email
Roofing Inspection Passed 11/21/2022 11/22/2022 11/22/2022
Silas Ebbert ((970) 870-5347)   Send Email
Drywall Inspection Not Ready 12/12/2022 12/13/2022 12/13/2022
Jeff Yeiser ((970) 870-5371)   Send Email
Framing Inspection Partial Pass 12/13/2022 12/13/2022
Jeff Yeiser ((970) 870-5371)   Send Email
Structural Inspection Partial Pass 4/4/2023 04/04/2023
Jeff Yeiser ((970) 870-5371)   Send Email
Drywall Inspection Partial Pass 4/10/2023 4/11/2023 04/11/2023
Jeff Yeiser ((970) 870-5371)   Send Email
Insulation Inspection Passed 4/10/2023 4/11/2023 04/11/2023
Jeff Yeiser ((970) 870-5371)   Send Email
Drywall Inspection Passed 5/2/2023 05/02/2023
Jeff Yeiser ((970) 870-5371)   Send Email

Conditions

Condition Status Department Category Expiration Date Due Date
Miscellaneous Open Fire Prevention Prior to Issuance of CO/CC
: The following items need corrected. 1. Address marking at least 3" in height, digits to be reflective and on a contrasting background. Address must be easy to see in day or night conditions from road way. 2. Schedule 40 gray plastic PVC pipe installed at the location of the propane tank shut off. Pole must be high enough to be seen during winter snow pack. 3. Fire district lock box must be permanently installed on the garage frame. Once these items are in installed fire district must inspect prior to approval of CO
Blower door test results Open Building Services Prior to Issuance of CO/CC
: Blower Door Test Results
Truss Drawings Deferred Submittal Open Building Services Prior to Insulaton Inspections Scheduled
: Truss drawings shall be submitted, reviewed and approved prior to installation and inspections.
Miscellaneous Resolved Planning and Land Use Prior to Rough Building Wall Inspections
: Cannot move beyond foundation until Planning resolution recorded (PL20220040)

Related Permit & Planning Applications

Reference Number Status Type
PREL220961 Closed Electrical
PRPL221752 Permit(s) Issued Plumbing
PRMH221753 Permit(s) Issued Mechanical
PRGS230658 Permit(s) Issued Gas