Summary

PRSF230553
New Single Family Dwelling
Permit(s) Issued
NOWOSIELSKI, RYAN DAVID & REBECCA ANN (JT)
New
R-3 - Residential, one- and two-family
New 1-Story Single Family Dwelling with walkout basement. Basement has approximately 1,634 SF of finished living space, Level One has approximately 1,640 SF of finished living space, Garage has approximately 823SF of unfinished space. (4)Bedrooms, (3) Full Bathrooms and (1) 1/2 Bathrooms and an attached 2-car Garage
06/08/2023
06/22/2023
06/22/2026

Locations

Submittals

1 Permit Application Submittal 06/08/2023      Status: Returned for Correction

Review Type Outcome Est. Completion Date Completed
GIS Land Development Review Approved 06/23/2023 06/19/2023
Lauren Wade ((970) 870-5465)   Send Email
Public Works Review Approved 06/23/2023 06/19/2023
Tony Brown ((970) 870-5344)   Send Email
Fire Code Review Failed 06/23/2023 06/17/2023
Doug Shaffer ((970) 871-8612)   Send Email
Miscellaneous
Carried Forward
06/21/2023


Resubmittal of site plan required with the following requirements for fire department access. Driveway grades shall not exceed 10%. NB
Resubmittal of site plan required with the following requirements for fire department access. Driveway grades shall not exceed 10%. NB
Building Code Review Approved 06/23/2023 06/16/2023
Ted Allen ((970) 870-5329)   Send Email
A foundation only building permit will initially be signed off on by Routt County Regional Building Department (RCRBD). Prior to RCRBD signing off on the full building permit, the following deferred items shall be submitted: DEFERRED SUBMITTALS 1. SITE RETAINING WALL ENGINEERING. 2. FIRE SPRINKLERS, AS REQUIRED. 3. HEAT LOAD CALCULATIONS. 4. ENGINEERED TRUSS DRAWINGS. 5. SPECIAL INSPECTION REPORTS Deferred blower door test reports and commissioning reports shall be submitted prior to issuance of CO.
Planning Review Approved 06/23/2023 06/13/2023
Michael Fitz ((970) 879-2704)   Send Email
Single-family home proposed on Lot 1of Country Green Subd. Applicant has received a variance for a north/front setback of 33'8", west/side setback of 29'6", and a retaining wall of max 16' with a north/front setback of 10' and west/side setback of 20'. Reference project PL20230034. This proposal complies with all varied dimensions, and all other zone district setbacks and height standards. Skyline and waterbody setback standards are OK, and there are no other Planning concerns. Per standard policy with variances, a Foundation Location Survey will be required prior to building vertical.
External Agencies Review Approved 06/23/2023 06/12/2023
Malea Michael-Ferrier ((970) 870-5334)   Send Email
YVEA - inspections@yvea.com Meter to be located as described by YVEA. They shall not be enclosed, covered or concealed. Violation shall result in termination of service. This approval addresses only the meter and service location. Please go to https://www.yvea.com/construction-service-guidelines to fill out all necessary applications and pay $250 application fee. Any questions call Emma at YVEA 970-871-2242
Environmental Health Review Failed 06/23/2023 06/12/2023
Amanda Williams ((970) 870-5588)   Send Email
SEPTIC (Canned language for reviews) *Application, application fee $1000.00 as well as OWTS engineered design & Site Plan *Please visit the Routt County website / Environmental Health / Apply for a septic permit / *Please call Environmental Health when application is completed, that is how we make the fee payable. Be sure to scroll all the way down to bottom of page for payment. *Upload engineered design and site plan to Documents and images on your application; this is located in the column on the right https://cityview2.iharriscomputer.com/RouttCountyPortal When paying folks must log into their City View account. They need to look for Environmental Health permits this is different from my permits. Once they find this they will click on their permit and move fees to cart and follow prompts for payment

2 Permit Application Submittal 06/20/2023      Status: Pending

Review Type Outcome Est. Completion Date Completed
Building Code Review Approved 08/04/2023 07/28/2023
Ted Allen ((970) 870-5329)   Send Email
Retaining wall structural; The owner and/or owners representative shall be responsible for contracting the special inspector and obtaining sufficient data throughout the rw construction to satisfy the requirements of the local governing authority to secure approval of the retaining wall construction and by performing the duties outlined in approved plans.
Fire Code Review Approved 06/28/2023 06/21/2023
Doug Shaffer ((970) 871-8612)   Send Email
Miscellaneous
Outstanding
06/21/2023


Resubmittal of site plan required with the following requirements for fire department access. Driveway grades shall not exceed 10%. NB
Conditionally Approved –NO INSPECTIONS deferred submittal until RECEIPT of Fire Alarm/Sprinkler plan/permits by sub-contractor to Fire Prevention. See www.steamboatsprings.net/Fire and EMS Services/Fire Prevention/Downloadable Permits and Forms. Fire sprinkler and monitored fire alarm required as additional fire protection measures due to driveway being over 10% grade. DJS
Environmental Health Review Approved 06/28/2023 06/21/2023
Amanda Williams ((970) 870-5588)   Send Email
Pertinent information received 6/19/2023

Fees

Paid Fees Amount Paid Owing Date Paid
Routt County Planning Dept Plan Review Fee $75.00 $75.00 Paid 06/08/2023
Steamboat Springs Fire Department: Plan Review Fee $25.00 $25.00 Paid 06/22/2023
Routt County Use Tax Fee $7,915.69 $7,915.69 Paid 06/22/2023
Building Permit Fee $5,666.40 $5,666.40 Paid 06/22/2023
Plan Review Fee $3,683.16 $3,683.16 Paid 06/08/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection Pending
Roofing Inspection Pending
Drywall Inspection Pending
Grading Inspection Pending
Mike Mordi   Send Email
Final Grading Inspection Pending
Tony Brown ((970) 870-5344)   Send Email
Building Final Inspection Pending
Foundation Water Proofing Pending
Foundation/Underslab Insulation Pending
Lath/Veneer Inspection Pending
Shower Pan Inspection Pending
Foundation Inspection Pending
Structural Inspection Pending
Foundation Inspection Partial Pass 10/27/2023 10/27/2023 10/27/2023
Jeff Yeiser ((970) 870-5371)   Send Email
Foundation Inspection Partial Pass 10/30/2023 10/30/2023 10/30/2023
Jeff Yeiser ((970) 870-5371)   Send Email
Insulation Inspection Partial Pass 11/14/2023 11/14/2023 11/14/2023
Jeff Yeiser ((970) 870-5371)   Send Email
Foundation Drain Inspection Partial Pass 11/22/2023 11/22/2023 11/22/2023
Silas Ebbert ((970) 870-5347)   Send Email
Foundation Drain Inspection Passed 12/1/2023 12/1/2023 12/01/2023
Jeff Yeiser ((970) 870-5371)   Send Email
Radon Piping Passed 12/18/2023 12/18/2023 12/18/2023
Jeff Yeiser ((970) 870-5371)   Send Email
Insulation Inspection Partial Pass 2/1/2024 2/1/2024 02/01/2024
Jeff Yeiser ((970) 870-5371)   Send Email
Framing Inspection Not Ready 3/1/2024 3/1/2024 03/01/2024
Jeff Yeiser ((970) 870-5371)   Send Email
Miscellaneous
Carried Forward
03/01/2024
1. Add H2.5 clips to rafters and trusses, not missed, not completed 2. Main door needs 2nd king 3. Garage trusses need one row ow bracing as specified

Wall/Roof Sheeting Passed 3/27/2024 3/27/2024 03/27/2024
Jeff Yeiser ((970) 870-5371)   Send Email
Framing Inspection Partial Pass 3/27/2024 3/27/2024 03/27/2024
Jeff Yeiser ((970) 870-5371)   Send Email
Miscellaneous
Resolved
03/27/2024
1. Add H2.5 clips to rafters and trusses, not missed, not completed 2. Main door needs 2nd king 3. Garage trusses need one row ow bracing as specified

Framing Inspection Passed 4/22/2024 4/22/2024 04/22/2024
Jeff Yeiser ((970) 870-5371)   Send Email
Insulation Inspection Passed 4/30/2024 4/30/2024 04/30/2024
Jeff Yeiser ((970) 870-5371)   Send Email
Structural Inspection Partial Pass 5/3/2024 05/03/2024
Jeff Yeiser ((970) 870-5371)   Send Email

Conditions

Condition Status Department Category Expiration Date Due Date
Certified Survey of Foundation Open Planning and Land Use Prior to Full Building Permit Issuance
: A foundation only building permit will initially be signed off on by Planning. Prior to Planning signing off on the full building permit, a certified survey of the location of the foundation forms must be submitted.
Miscellaneous Open Building Services Prior to Full Building Permit Issuance
: A foundation only building permit will initially be signed off on by Routt County Regional Building Department (RCRBD). Prior to RCRBD signing off on the full building permit, the following deferred items shall be submitted: DEFERRED SUBMITTALS 1. SITE RETAINING WALL ENGINEERING. 2. FIRE SPRINKLERS, AS REQUIRED. 3. HEAT LOAD CALCULATIONS. 4. ENGINEERED TRUSS DRAWINGS. 5. SPECIAL INSPECTION REPORTS
Blower door test results Open Building Services Prior to Issuance of TCO/CO/CC
: Deferred blower door test reports and commissioning reports shall be submitted prior to issuance of CO/TCO.
Design Engineer on-site Wastewater final report Open Environmental Health Prior to Issuance of TCO/CO/CC
: Design Engineer on-site Wastewater final report, including as Built plans.
Miscellaneous Resolved Fire Prevention Prior to Rough Building Wall Inspections
: Conditionally Approved –NO INSPECTIONS deferred submittal until RECEIPT of Fire Alarm/Sprinkler plan/permits by sub-contractor to Fire Prevention. See www.steamboatsprings.net/Fire and EMS Services/Fire Prevention/Downloadable Permits and Forms
Final Fire Inspection Required Open Fire Prevention Prior to Issuance of TCO/CO/CC
: Final Fire Alarm and Sprinkler Inspections Required
Miscellaneous Open Building Services Prior to Issuance of TCO/CO/CC
: The owner and/or owners representative shall be responsible for contracting the special inspector and obtaining sufficient data throughout the rw construction to satisfy the requirements of the local governing authority to secure approval of the retaining wall construction and by performing the duties outlined in approved plans.

Related Permit & Planning Applications

Reference Number Status Type
PREL231001 Permit(s) Issued Electrical
PRPL231086 Permit(s) Issued Plumbing
PRMH231087 Permit(s) Issued Mechanical
PRMH240292 Permit(s) Issued Mechanical
PREL240308 Permit(s) Issued Electrical

Documents & Images

Date Uploaded File Type Name
06/08/2023 CSMP Plan_34620 Country Green_6-8-23
06/08/2023 Improvement Survey Plat_34620 Country Green_6-8-23
06/08/2023 Permit Checklist_34620 Country Green_6-8-23
06/22/2023 Plans Architectural Plans - Comment Corrections 34620 Country Green_Nowosielski - 2023_06_20 (Received) (Stamped)
06/08/2023 Report Soils Report_34620 Country Green_6-8-23
06/22/2023 Plans Utility_34620 Country Green_6-8-23 (Received) (Stamped)
06/22/2023 Plans Civil Plans_34620 Country Green_6-8-23 (Received) (Stamped)
06/22/2023 Plans Site Plan_34620 Country Green_6-8-23 (Received) (Stamped)
06/22/2023 Plans Structural_34620 Country Green_6-8-23 (Received) (Stamped)
06/08/2023 Receipt Receipt for transaction:2023-000590
06/20/2023 Letter Permit Review Corrections Notice (Generate/Send Correction Notice)
06/20/2023 Narrative of Comment Corrections Response - PRSF230553
06/22/2023 Letter Permit - Detailed
06/22/2023 Receipt Receipt for transaction:2023-000712
07/28/2023 Plans Retaining Wall_34620 Country Green_Design Report (Stamped)
09/28/2023 Plans Retaining Wall_34620 Country Green_Engineered Plans (Stamped)
07/28/2023 Plans Retaining Wall_34620 Country Green_Quantity Estimate (Stamped)
10/27/2023 Report Inspection Report (Foundation Inspection)
10/30/2023 Report Inspection Report (Foundation Inspection)
11/14/2023 Report Inspection Report (Insulation Inspection)
11/22/2023 Report Inspection Report (Foundation Drain Inspection)
12/01/2023 Report Inspection Report (Foundation Drain Inspection)
12/18/2023 Report Inspection Report (Radon Piping)
02/01/2024 Report Inspection Report (Insulation Inspection)
03/01/2024 Report Inspection Report (Framing Inspection)
03/27/2024 Report Inspection Report (Wall/Roof Sheeting)
03/27/2024 Report Inspection Report (Framing Inspection)
04/22/2024 Report Inspection Report (Framing Inspection)
04/30/2024 Report Inspection Report (Insulation Inspection)
05/03/2024 Report Inspection Report (Structural Inspection)