Summary

PRSP220480
On-Site Wastewater
In Progress
BLANDFORD, JANE W.H. & DAVID M. (JT)
New
New OWTS for the secondary dwelling that will be tied in to the Primary residence leach feild.
05/05/2022
01/15/2024

Locations

Submittals

1 Permit Application Submittal 05/05/2022      Status: Submittal Accepted

Review Type Outcome Est. Completion Date Completed
COO Review - Environmental Health VOID 05/13/2022 05/09/2022
Rick Melzer ((970) 870-5588)   Send Email
New design for primary and secondary dwelling unit. The previously submitted and approved Onsite Wastewater Treatment System(OWTS) design for the primary residence(B-20-809) was for a two bedroom residence with a possible addition of two bedrooms. Primary residence was built with four bedrooms and the secondary dwelling (PRAU220370) unit is a proposed two bedroom. Per my conversation with the engineer at NWCC the new design incorporates both the primary and secondary dwelling unit. The original owts permit issued is no longer valid. Chamber/Trench. Soil Type 2A. Eighty-seven Quick 4(4 runs). 2,000 three compartment(primary) & 1,250 three compartment(SDU).
Environmental Health Review Approved 05/12/2022 05/09/2022
Rick Melzer ((970) 870-5588)   Send Email
OWTS
Outstanding
05/18/2022


New design for primary and secondary dwelling unit. The previously submitted and approved Onsite Wastewater Treatment System(OWTS) design for the primary residence(B-20-809) was for a two bedroom residence with a possible addition of two bedrooms. Primary residence was built with four bedrooms and the secondary dwelling (PRAU220370) unit is a proposed two bedroom. Per my conversation with the engineer at NWCC the new design incorporates both the primary and secondary dwelling unit. The original owts permit issued is no longer valid. Chamber/Trench. Soil Type 2A. Eighty-seven Quick 4(4 runs). 2,000 three compartment(primary) & 1,250 three compartment(SDU).

Fees

Paid Fees Amount Paid Owing Date Paid
New OWTS $700.00 $700.00 Paid 05/06/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

There are no inspections for this development permit application.

Conditions

Condition Status Department Category Expiration Date Due Date
Design Engineer on-site Wastewater final report Resolved Environmental Health Prior to Issuance of TCO/CO/CC
: Design Engineer on-site Wastewater final report, including as Built plans.

Related Permit & Planning Applications

There are no related items for this development permit application.