CityView Portal

Development Permit Application Status

PRSP221791


You will only be able to schedule inspections if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRSP221791
On-Site Wastewater
Closed
DUKSA FAMILY, LLC
New
New On site Waste Water for a single restroom in the office at the recycle center.
12/19/2022
04/24/2023
12/12/2023

Locations

Submittals

1 Permit Application Submittal 12/19/2022      Status: Pending

Review Type Outcome Est. Completion Date Completed
Environmental Health Review Approved 12/27/2022 07/26/2023
Christopher Peters ((970) 870-5354)   Send Email
Good Morning Mr. Duksa, I am following up on our phone conversation concerning the OWTS design for 40025 Baker Way. Our biggest concern with the submitted design is the soils classification of Type “O”. This classification was used in the 2013-2017 CDPHE OWTS regulation, but is no longer valid. Type “O” were classified as sandy soils with greater than 35% rocks. In the current Reg. 43, this soil profile would be considered a Type “R” soil. Type R soils require an unlined sand filter with pressure distribution. The soil should be further classified to determine the subclass of type “R” soil (e.g. R-0, R-1, R-2) to calculate the bed sizing and depth. Additionally, we have concerns regarding the depth to groundwater identified in the design report. The report states that groundwater was not encountered to depth of 11’ bgs. Based on the proximity of the OWTS to the Yampa River and recent above average precipitation, it appears that groundwater should be much closer to the ground surface. RCDEH is hesitant to issue a permit for any subterranean soil treatment area at this property, until the depth to groundwater and soil type is field confirmed. Based on the current information, it appears a mounded, unlined sand filter with pressure distribution will be required to meet the limitations present at the construction site. Please feel free to reach out to RCDEH with additional questions.
Environmental Health Review Approved 12/27/2022 04/24/2023
Amanda Williams ((970) 870-5588)   Send Email
Design to be reviewed once fees for a new septic system have been paid.

Fees

Paid Fees Amount Paid Owing Date Paid
New OWTS $700.00 $700.00 Paid 04/12/2023
$1,000.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Preliminary Soil Classification Passed 07/26/2023
Christopher Peters ((970) 870-5354)   Send Email
Installation Inspection Passed w/ Conditions 11/28/2023 11/28/2023
Christopher Peters ((970) 870-5354)   Send Email

Conditions

Condition Status Department Category Expiration Date Due Date
Design Engineer on-site Wastewater final report Resolved Environmental Health Prior to Issuance of TCO/CO/CC
: As-Built report from Greg Hermann received 12/12/2023 [Christopher Peters @ 12/12/2023 11:14 AM] Design Engineer on-site Wastewater final report, including as Built plans.

Related Permit & Planning Applications

There are no related items for this development permit application.

Documents & Images

Date Uploaded File Type Name
01/05/2023 Letter Incomplete Application Notice (Generate/Send Incomplete Application Notice)
01/05/2023 Letter Incomplete Application Notice
01/05/2023 Letter Incomplete Application Notice
04/12/2023 Receipt Receipt for transaction:2023-000277
07/26/2023 Plans D&DOWTSRev3
12/12/2023 Report Adobe Scan Dec 12, 2023