Permit Application Status

B0300309


In order to schedule inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

B0300309
Building Permit - Commercial
Final Completion
NEW OTHER
UTILITY, MISCELLANEOUS
BARN
02/28/2003
02/28/2003
08/27/2003
01/20/2004

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 08/27/2003 10/29/2010

Fees

Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $374.00 $374.00 Paid 02/28/2003
25 Electrical Permit Fee $35.00 $35.00 Paid 02/28/2003
25 Electrical Permit Fee $20.00 $20.00 Paid 05/16/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Not Ready 06/30/2004
Corrections:


Correction
Corrective Action Required
06/30/2004
READINESS FOR INSPECTION ALSO, NO RECORD OF 3RD PARTY SOIL BEARING INSPECTION WORK REQUESTED FOR INSP NOT COMPLETED

Footing Inspection - Commercial Partial 07/01/2004
Corrections:


Correction
Partial Correction
07/01/2004
FRAME FOOTINGS + CONNECTING RAT WALL OK TO POUR WHEN READY: SOUTH WALL + S 12` OF N-S CROSS TIES EXCLUDING SW CORNER PIER & SECTION FROM 65` E TO 105` E OF SW CORNER; ENSURE BAR COVERAGE @ >= 3" TO BOTTOMS/BANKS

Correction
Resolved
07/01/2004
READINESS FOR INSPECTION

Footing Inspection - Commercial Partial 07/12/2004
Corrections:


Correction
Partial Correction
07/12/2004
FRAME FOOTINGS + CONNECTING RAT WALL OK TO POUR WHEN READY: SOUTH WALL + S 12` OF N-S CROSS TIES EXCLUDING SW CORNER PIER & SECTION FROM 65` E TO 105` E OF SW CORNER; E WALL + E 15` OF N WALL; ENSURE BAR COVERAGE @ >= 3" TO BOTTOMS/BANKS

Footing Inspection - Commercial Partial 07/14/2004
Corrections:


Correction
Partial Correction
07/14/2004
FRAME FOOTINGS + CONNECTING RAT WALL OK TO POUR WHEN READY: SOUTH WALL + S 12` OF N-S CROSS TIES EXCLUDING SW CORNER PIER & SECTION FROM 65` E TO 105` E OF SW CORNER; E WALL + E 15` OF N WALL; E 125` OF N WALL + INCLUDED CROSS TIES; ENSURE BAR COVERAGE @ >= 3" TO BOTTOMS/BANKS

Footing Inspection - Commercial Partial 07/15/2004
Corrections:


Correction
Partial Correction
07/15/2004
FRAME FOOTINGS + CONNECTING RAT WALL OK TO POUR WHEN READY: SOUTH WALL + S 12` OF N-S CROSS TIES EXCLUDING SW CORNER PIER & SECTION FROM 65` E TO 105` E OF SW CORNER; E WALL + E 15` OF N WALL; E 175` OF N WALL + INCLUDED CROSS TIES; ENSURE BAR COVERAGE @ >= 3" TO BOTTOMS/BANKS

Footing Inspection - Commercial Partial 07/21/2004
Corrections:


Correction
Partial Correction
07/21/2004
FRAME FOOTINGS + CONNECTING RAT WALL OK TO POUR WHEN READY: SOUTH WALL + S 12` OF N-S CROSS TIES EXCLUDING SW CORNER PIER & SECTION FROM 65` E TO 105` E OF SW CORNER; E WALL + E 15` OF N WALL; E 175` OF N WALL + INCLUDED CROSS TIES; W WALL + W 10` OF N WALL; ENSURE BAR COVERAGE @ >= 3" TO BOTTOMS/BANKS

Footing Inspection - Commercial Partial 07/22/2004
Corrections:


Correction
Partial Correction
07/22/2004
INTERIOR CROSS-TIES OK TO POUR WHEN READY: #1; NUMBERING EAST TO WEST ENSURE BAR COVERAGE

Correction
Resolved
07/22/2004
FRAME FOOTINGS + CONNECTING RAT WALL OK TO POUR WHEN READY: S WALL + S 12` OF N-S CROSS TIES EXCLUDING SW CORNER PIER & SECTION FROM 65` E TO 105` E OF SW CORNER; E WALL + E 15` OF N WALL; E 175` OF N WALL + INCL CROSS TIES; W WALL + W 10` OF N WALL; W 60` OF N WALL TO COMPLETE PERIMETER ENSURE BAR COVERAGE @ >= 3" TO BOTTOMS/BANKS

Footing Inspection - Commercial Partial 07/30/2004
Corrections:


Correction
Partial Correction
07/30/2004
INTERIOR CROSS-TIES OK TO POUR WHEN READY: #1; #2; #3; NUMBERING EAST TO WEST ENSURE BAR COVERAGE

Footing Inspection - Commercial Not Ready 08/02/2004
Corrections:


Correction
Partial Correction
08/02/2004
INTERIOR CROSS-TIES OK TO POUR WHEN READY: #1; #2; #3; #4 NOT READY NUMBERING EAST TO WEST ENSURE BAR COVERAGE

Footing Inspection - Commercial Partial 08/03/2004
Corrections:


Correction
Partial Correction
08/03/2004
INTERIOR CROSS-TIES OK TO POUR WHEN READY: #1; #2; #3; #4; #5; #8; #9; NUMBERING EAST TO WEST ENSURE BAR COVERAGE

Correction
Resolved
08/03/2004
FRAME FOOTINGS + CONNECTING RAT WALL

Footing Inspection - Commercial Partial 08/11/2004
Corrections:


Correction
Partial Correction
08/11/2004
FRAME FOOTINGS + CONNECTING RAT WALL OK TO POUR WHEN READY REMAINDER OF S WALL + PART OF SOUTH BUMP-OUT

Footing Inspection - Commercial Passed 08/12/2004
Corrections:


Correction
Resolved
08/12/2004
INTERIOR CROSS-TIES #1; #2; #3; #4; #5; #8; #9 #6; #7 OK TO POUR AFTER SPECIFIED RE-BAR CORRECTIONS ARE COMPLETED. NUMBERING EAST TO WEST ENSURE BAR COVERAGE

Correction
Resolved
08/12/2004
FRAME FOOTINGS + CONNECTING RAT WALL TO COMPLETE PERIMETER GRADE BEAMS & INTEGRAL COLUMN FOOTINGS. OK TO POUR WHEN READY REMAINDER OF SOUTH BUMP-OUT

Electrical Service Inspection Not Ready 05/04/2005
Corrections:


Correction
Corrective Action Required
05/04/2005
ELECTRICAL SERVICE INSTALLATION TWO 200 AMP PANELS INSTALLED. NOTE: IF NO WATER LINE GROUND EACH PANEL MUST HAVE APPROVED GROUND VIA TWO 1/2" x 8' GROUND RODS DRIVEN AT LEAST 6' APART. NOT PER PERMIT WHICH SAYS ONE 200 AMP PANEL

Electrical Service Inspection Passed 05/17/2005
Corrections:


Correction
Resolved
05/17/2005
ELECTRICAL SERVICE INSTALLATION TWO 200 AMP PANELS RELEASE SERV ICE

Water Service Inspection Not Ready 03/20/2006
Corrections:


Correction
Corrective Action Required
03/20/2006
STATUS OF SERVICE INSTALLATION APPROVAL SERICE LINE WAS INSTALLED AND COVERED WITHOUT APPROVAL. NOTICE OF VIOLATION TO BE ISSUED NO INSPECTION REQUEST + NO APPROVAL OF RECORD

Water Service Inspection Not Ready 03/27/2006
Corrections:


Correction
Corrective Action Required
03/27/2006
STATUS OF SERVICE INSTALLATION APPROVAL SERVICE LINE WAS INSTALLED AND COVERED WITHOUT APPROVAL. NOTICE OF VIOLATION HAS BEEN ISSUED. 3/27/06 MET W/ JOHN IVEY ON-SITE TO DISCUSS REQUIREMENTS FOR APPROVAL. NO INSPECTION REQUEST + NO APPROVAL OF RECORD

Occupancy Inspection - Codes Commercial Not Ready 05/05/2006
Corrections:


Correction
Corrective Action Required
05/05/2006
OCCUPANCY APPROVAL STATUS NO RECORD OF FINAL INSPECTION REQUESTED OR PERFORMED ON SHELL BUILDING OR OFFICE AREA. NOTICE OF VIOLATION HAS BEEN ISSUED THIS DATE. ARENA AREA IN USE WITHOUT APPROVAL

Correction
Corrective Action Required
05/05/2006
Receive Fire Department approval

Water Service Inspection Not Ready 05/09/2006
Corrections:


Correction
Corrective Action Required
05/09/2006
STATUS OF SERVICE INSTALLATION APPROVAL SERVICE LINE WAS INSTALLED AND COVERED WITHOUT APPROVAL. NOTICE OF VIOLATION HAS BEEN ISSUED. 3/27/06 MET W/ JOHN IVEY ON-SITE TO DISCUSS REQUIREMENTS FOR APPROVAL. NO INSPECTION REQUEST + NO APPROVAL OF RECORD

Occupancy Inspection - Codes Commercial Failed 05/09/2006
Corrections:


Correction
Corrective Action Required
05/09/2006
OCCUPANCY APPROVAL STATUS SEE PERMIT B0501070

Correction
Corrective Action Required
05/09/2006
Receive Fire Department approval SEE PERMIT B0501070

Correction
Corrective Action Required
05/09/2006
Receive Water Utilities Approval SEE PERMIT B0501070

Final Inspection - Commercial Failed 05/09/2006
Corrections:


Correction
Partial Correction
05/09/2006
TEMPORARY USE AUTHORIZATION STATUS SEE PERMIT B0501070

Occupancy Inspection - Codes Commercial Failed 05/11/2006
Corrections:


Correction
Resolved
05/11/2006
Receive Fire Department approval PER J DIR 5/10/06

Occupancy Inspection - Codes Commercial Failed 05/18/2006
Final Inspection - Commercial Failed 05/18/2006
Corrections:


Correction
Corrective Action Required
05/18/2006
TEMPORARY USE AUTHORIZATION STATUS SEE PERMIT B0501070

Occupancy Inspection - Codes Commercial Passed 05/30/2006
Corrections:


Correction
Resolved
05/30/2006
OCCUPANCY APPROVAL STATUS

Correction
Resolved
05/30/2006
Receive Water Utilities Approval PER BEN HASKAMP 5/26/06

Final Inspection - Commercial Passed 05/30/2006
Corrections:


Correction
Resolved
05/30/2006
TEMPORARY USE AUTHORIZATION STATUS

Correction
Resolved
05/30/2006
CLOSE PERMIT IN CONJUCTION WITH FINISH PERMIT B0501070

Water Service Inspection Passed 05/31/2006
Corrections:


Correction
Resolved
05/31/2006
STATUS OF SERVICE INSTALLATION APPROVAL