B0501070


In order to schedule inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

B0501070
Building Permit - Commercial
Certificate of Occupancy
ADDITION COMMERCIAL
NOT APPLICABLE
INTERIOR FINISH AND EXTERIOR ADDITION
06/22/2005
11/09/2005
05/08/2006
05/31/2006

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 05/06/2006 10/29/2010

Fees

Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $377.00 $377.00 Paid 11/09/2005
24 BLDG Plan Check Fees $26.25 $26.25 Paid 11/09/2005
25 Electrical Permit Fee $60.00 $60.00 Paid 11/09/2005
25 Mechanical Permit Fees $125.50 $125.50 Paid 11/09/2005
25 Plumbing Permit Fees $47.50 $47.50 Paid 11/09/2005
84 Water Meters $125.00 $125.00 Paid 11/09/2005
85 Water Taps $2,734.00 $2,734.00 Paid 11/09/2005
Right of Way Permit $35.00 $35.00 Paid 11/09/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Partial 12/27/2005
Corrections:


Correction
Partial Correction
12/27/2005
NOT AS SHOWN ON PLANS REVISED PLUMBING DRAWINGS REQUIRED.OFFICE BATHROOM IS NOT LAYED OUT AS SHOWN ON APPROVED PLANS. ALSO HOLDING TANK WILL BE ON THE EAST SIDE OF THE BUILDING AND IT IS SHOWN ON THE WEST SIDE. POUR FLOOR AT OWNERS RISK IF POURED PRIOR TO GROUND PLUMBING APP

All Rough Inspection - Commercial Not Ready 02/07/2006
Corrections:


Correction
Corrective Action Required
02/07/2006
READINESS FOR INSPECTION EXAMPLES: TACK ROOMS / GRAIN ROOM ADDITION NOT PER DRAWING AND SOME WORK ALREADY COVERED WITH NO INSPECTION ON RECORD. WORK VARIES FROM DRAWINGS + WORK ALREADY COVERED

Underslab Plumbing Inspection - Commercial Passed 02/09/2006
Corrections:


Correction
Resolved
02/09/2006
NOT AS SHOWN ON PLANS DRAWINGS REVISED

All Rough Inspection - Commercial Failed 02/09/2006
Corrections:


Correction
Corrective Action Required
02/09/2006
OFFICE AREA RESTROOMS + CONNECT ELECT BRANCH CIRCUIT GROUND CONDUCTORS PER NEC XTEND PLMB VENT THRU ROOF + DUCT RESTROOM VENT FANS

Correction
Corrective Action Required
02/09/2006
STABLE (NORTH) ADDITION ELECTRICAL BOXES MUST BE FLUSH W/ COMBUSTIBLE WALL SURFACES + CHECK ALL ELECTRICAL BRANCH WIRING FOR PROPER CONNECTIONS OF GROUND CONDUCTORS XTEND PLMG VENT THRU ROOF + SHIELD PLATE PVC PIPE +

Correction
Resolved
02/09/2006
READINESS FOR INSPECTION

All Rough Inspection - Commercial Not Ready 02/10/2006
All Rough Inspection - Commercial Partial 02/13/2006
Corrections:


Correction
Resolved
02/13/2006
OFFICE AREA RESTROOMS WALLS + CEILING OK TO COVER WHEN READY

Correction
Resolved
02/13/2006
STABLE (NORTH) ADDITION CHANGE 1 MUD RING TO 5/8" THEN WALLS OK TO COVER

Correction
Partial Correction
02/13/2006
READINESS FOR INSPECTION STABLE + RESTROOMS ONLY

Occupancy Inspection - Codes Commercial Failed 02/15/2006
Corrections:


Correction
Corrective Action Required
02/15/2006
OCCUPANCY OF STABLE AREA DRIVEWAY NOT TRAVERSIBLE BY FIRE DEPT NOT READY 2/15/06 UNPAID LICENSE TAX +

Correction
Corrective Action Required
02/15/2006
Receive Planning & Development Approval

Correction
Corrective Action Required
02/15/2006
Receive Public Works Approval

Correction
Corrective Action Required
02/15/2006
Receive Water Utilities Approval

Correction
Corrective Action Required
02/15/2006
Receive Fire Department approval

Correction
Resolved
02/15/2006
READINESS FOR INSPECTION AFTER SCHEDULED INSPECTION PAYMENT OF LICENSE TAX RECEIVED 2/15/06

Occupancy Inspection - Codes Commercial Failed 02/15/2006
Corrections:


Correction
Corrective Action Required
02/15/2006
WATER & SEWER SERVICES NO RECORD OF APPROVAL

Occupancy Inspection - Codes Commercial Failed 02/16/2006
Corrections:


Correction
Corrective Action Required
02/16/2006
APPROVED DRAWINGS PROVIDE UPDATED, APPROVED DRAWINGS.

Correction
Corrective Action Required
02/16/2006
UNUSED PLUMBING CAP UNUSED WASTE PIPE NEAR WATER HEATER. UTILITY ROOM

Correction
Corrective Action Required
02/16/2006
PROTECTION FROM FREEZING PROVIDE HEAT TO FACILITY PER ENGINEERED DRAWINGS.

Correction
Corrective Action Required
02/16/2006
Grading (IRC) COMPLETE INSTALLATION OF DOWNSPOUT PIPING. WATER TO BE DIRECTED MINIMUM 36" AWAY FROM FOUNDATION EXTERIOR

Correction
Corrective Action Required
02/16/2006
ELECTRICAL LABELING LABEL PANEL TO MATCH BREAKER LABEL AT MAIN SERVICE PANEL. UTILITY ROOM

Correction
Corrective Action Required
02/16/2006
NOTE INSPECTION ON 2/16/06 APPLIES TO STABLE AREA ONLY.

Correction
Corrective Action Required
02/16/2006
PROPERTY IDENTIFICATION PROVIDE COMPLIANT ADDRESSING OF BUILDING.

Correction
Corrective Action Required
02/16/2006
WATER & SEWER NO HISTORY OF WATER OR SEWER INSPECTIONS. NOTE: WATER PIPE AT EAST END OF BUILDING BURIED LESS THAN 24" BELOW GRADE. MUST BE LOWERED TO CORRECT DEPTH. UNCOVER FOR INSPECTION

Correction
Partial Correction
02/16/2006
Receive Fire Department approval APPROVAL FROM CAPTAIN DIRR FOR STORAGE OF HORSES ONLY. USE OF ADJACENT FACILITY PROHIBITED.

Occupancy Inspection - Codes Commercial Failed 02/21/2006
Erosion Control Inspection Residential Passed 04/10/2006
Water Service Inspection Failed 04/10/2006
Corrections:


Correction
Corrective Action Required
04/10/2006
WATER LOCATION UNABLE TO LOCATE ANY WATER PIPE OR METER READY FOR INSPECTION. CALL FOR INISPECTION WHEN SOMEONE CAN MEET ME HERE TO FOR THE INSPECTION.

Water Service Inspection Failed 04/11/2006
Corrections:


Correction
Resolved
04/11/2006
WATER LOCATION UNABLE TO LOCATE ANY WATER PIPE OR METER READY FOR INSPECTION. CALL FOR INISPECTION WHEN SOMEONE CAN MEET ME HERE TO FOR THE INSPECTION.

Correction
Corrective Action Required
04/11/2006
COMMENTS 1- EXPOSE PIPES FOR INSPECTION. MUST BE ENOUGH TO SHOW PIPE MATERIAL STAMP. 2- COVER ENTIRE METER BELL. 3- PROVIDE WRITTEN VERIFICATION FROM WATER DEPARTMENT FOR METER LOCATION APPROVAL.

Water Service Inspection Not Ready 05/05/2006
Corrections:


Correction
Corrective Action Required
05/05/2006
REQUESTED INSPECTION 5/5/06 PIPE EXPOSED NEAR METER -- APPROX 42" DEEP PIPE EXPOSED NEAR BUILDING -- APPROX 36" DEEP NO INTERMEDIATE INSPECTION HOLES INDICATED OR FOUND SAMPLE OF PIPE OBTAINED FOR VERIFICATION OF ACCEPTABILITY PERMIT HOLDER NOT PRESENT

Occupancy Inspection - Codes Commercial Failed 05/09/2006
Corrections:


Correction
Corrective Action Required
05/09/2006
Receive Fire Department approval COORDINATE W/ CPT DIR

Correction
Corrective Action Required
05/09/2006
Receive Water Utilities Approval COORDINATE W/ BEN HASKAMP PHONE 816-969-1930

Correction
Resolved
05/09/2006
Receive Public Works Approval NO ISSUES PRESENTED

Correction
Resolved
05/09/2006
Receive Planning & Development Approval NO ISSUES PRESENTED

Correction
Resolved
05/09/2006
OCCUPANCY OF STABLE AREA

Correction
Corrective Action Required
05/09/2006
WATER & SEWER SERVICES NO RECORD OF APPROVAL OF WATER SERVICE

Correction
Corrective Action Required
05/09/2006
WATER & SEWER WATER SERVICE LINE UNCOVER FOR INSPECTION

Correction
Corrective Action Required
05/09/2006
PROPERTY IDENTIFICATION DURABLE; PERMANENT; VISIBLE HEIGHT DISPLAY ADDRESS AT BLDG AND AT CLIFFORD ROAD

Correction
Resolved
05/09/2006
NOTE

Correction
Resolved
05/09/2006
ELECTRICAL LABELING

Correction
Resolved
05/09/2006
Grading (IRC)

Correction
Corrective Action Required
05/09/2006
PROTECTION FROM FREEZING OR REVISE DRAWINGS TO OMIT HEAT AT PROPERTY OWNER'S RISK PROVIDE HEAT TO FACILITY PER ENGINEERED DRAWINGS

Correction
Corrective Action Required
05/09/2006
UNUSED PLUMBING NEAR WATER HEATER. UTILITY ROOM CAP UNUSED WASTE PIPE

Correction
Resolved
05/09/2006
APPROVED DRAWINGS

Correction
Corrective Action Required
05/09/2006
PLUMBING VENT STACK @ RESTROOMS NOT VENTED THRU ROOF AIR ADMITTANCE VALVE N.A.

Correction
Corrective Action Required
05/09/2006
ELECTRICAL PANELS SCREW FULL PERIMETER OF PANEL FRONTS PLUG UNUSED OPENINGS + USED LISTED HANDLE TIES +

Correction
Corrective Action Required
05/09/2006
SWITCH BOX MOUNTED @ LEFT SIDE OF S. ELECTRICAL SVC PANEL SUPPORT TO STRUCTURE + PLUG UNUSED OPENINGS

Correction
Corrective Action Required
05/09/2006
RESTROOM FLOORS NOT ABSORPTION-SEALED

Occupancy Inspection - Codes Commercial Failed 05/11/2006
Corrections:


Correction
Resolved
05/11/2006
Receive Fire Department approval PER J DIR 5/10/06

Occupancy Inspection - Codes Commercial Failed 05/18/2006
Corrections:


Correction
Resolved
05/18/2006
READINESS FOR INSPECTION PAYMENT OF LICENSE TAX RECEIVED 2/15/06

Correction
Corrective Action Required
05/18/2006
Receive Water Utilities Approval COORDINATE W/ BEN HASKAMP PHONE 816-969-1930

Correction
Resolved
05/18/2006
WATER & SEWER SERVICES SEE WATER UTILITIES NO CITY SEWER CONNECTION

Correction
Resolved
05/18/2006
WATER & SEWER SEE WATER UTILITIES

Correction
Resolved
05/18/2006
PROPERTY IDENTIFICATION

Correction
Corrective Action Required
05/18/2006
PROTECTION FROM FREEZING OR REVISE DRAWINGS TO OMIT HEAT AT PROPERTY OWNER'S RISK PROVIDE HEAT TO FACILITY PER ENGINEERED DRAWINGS

Correction
Resolved
05/18/2006
UNUSED PLUMBING

Correction
Resolved
05/18/2006
PLUMBING VENT STACK @ RESTROOMS

Correction
Resolved
05/18/2006
ELECTRICAL PANELS

Correction
Resolved
05/18/2006
SWITCH BOX MOUNTED @ LEFT SIDE OF S. ELECTRICAL SVC PANEL

Correction
Resolved
05/18/2006
RESTROOM FLOORS

All Rough Inspection - Commercial Passed 05/18/2006
Corrections:


Correction
Resolved
05/18/2006
READINESS FOR INSPECTION

Correction
Resolved
05/18/2006
STABLE (NORTH) ADDITION

Correction
Resolved
05/18/2006
OFFICE AREA RESTROOMS

Water Service Inspection Passed 05/18/2006
Corrections:


Correction
Resolved
05/18/2006
WATER LOCATION

Correction
Resolved
05/18/2006
COMMENTS

Correction
Resolved
05/18/2006
REQUESTED INSPECTION 5/5/06

Correction
Resolved
05/18/2006
SEE WATER UTILITIES INSPECTION ITEM

Occupancy Inspection - Codes Commercial Failed 05/19/2006
Corrections:


Correction
Corrective Action Required
05/19/2006
Receive Water Utilities Approval COORDINATE W/ BEN HASKAMP PHONE 816-969-1930

Correction
Resolved
05/19/2006
PROTECTION FROM FREEZING AT PROPERTY OWNER'S RISK ENGINEERED DRAWINGS REVISED TO OMIT HEATING

Occupancy Inspection - Codes Commercial Passed 05/30/2006
Corrections:


Correction
Resolved
05/30/2006
Receive Water Utilities Approval PER BEN HASKAMP 5/26/06 PHONE 816-969-1930