1 Permit Application Submittal 03/18/2022      Status: Returned for Correction

Review Type Outcome Est. Completion Date Completed
Planning Review Failed 04/06/2022 04/07/2022
Malea Michael-Ferrier ((970) 870-5334)   Send Email
Review will not be completed at this time. The Amended PUD Plan must be finalized and recorded before any review can be started.
GIS Land Development Review Failed 04/06/2022 04/07/2022
Jason Blair ((970) 870-5465)   Send Email
Miscellaneous
Carried Forward
07/27/2022


Please revise site plan to show new location of structure
Revised site plan required. Site plan must show existing and proposed location of structure
Environmental Health Review Failed 04/06/2022 04/06/2022
Scott Cowman ((970) 870-5401)   Send Email
Provide information on septic systems to ensure adequate size and function, as well as appropriate permitting of all systems.
Building Code Review Failed 04/06/2022 04/05/2022
Ted Allen ((970) 870-5329)   Send Email
See Document Markups
Carried Forward
07/27/2022


Based on the Work Description ? Existing Log Office Building will be moved and placed on a new foundation and a new bathroom will be added, The Home Ranch has been operating as a guest ranch since 1978. It has been open to the public since then.there have been revisions to their PUD over the years and they also have associated permits such as horseback riding or cross country ski tours as an amenity to the ranch. Routt County Regional Building Department (RCRBD) typically requires the architect or registered design professional to provide a code analysis using the 2018 International Building Code. IBC Chapter 29 regulates the minimum number of plumbing fixtures that must be provided for every type of building. The regulations in this chapter come directly from Chapters 3 and 4 of the International Plumbing Code (IPC). Provide a calculation to show that total of water closets, lavatories and service sinks that are to be provided to include provisions for accessibility, as applicable. Include architectural plans showing room uses, dimensions required to verify code requirements, accessibility, etc.
See Document Markups
Carried Forward
07/27/2022


Relocation of the historic huts along with many other recently approved projects under the PUD require building permits. Please open permits with architectural and engineering plans with documentation of permits or supporting documents in support of proposed use(s).
Public Works Review Approved 04/06/2022 04/04/2022
Tony Brown ((970) 870-5344)   Send Email
External Agencies Review Approved 04/06/2022 03/29/2022
Malea Michael-Ferrier ((970) 870-5334)   Send Email
N. Routt Fire - chief@northrouttfire.org No issues with project.

2 Permit Application Submittal 04/07/2022      Status: Returned for Correction

Review Type Outcome Est. Completion Date Completed
Environmental Health Review Failed 08/03/2022 08/04/2022
Heather Savalox ((970) 870-5588)   Send Email
Relocation of building with plumbing requires connection to existing septic system. Contact EH with more details; minor permit/repair fee required: https://cityview2.iharriscomputer.com/RouttCountyPortal
GIS Land Development Review Approved 08/03/2022 07/29/2022
Jason Blair ((970) 870-5465)   Send Email
Miscellaneous
Outstanding
07/27/2022


Please revise site plan to show new location of structure
Address
Outstanding
07/29/2022


Address identification must be provided for visibility from the street or public way and on the building front ingress doorway. Minimum stroke width is 1/2" and height is 4", must be contrasting color for visibility.
New sub-address unit designator assigned for Office: Unit K
Building Code Review Failed 08/03/2022 07/28/2022
Ted Allen ((970) 870-5329)   Send Email
See Document Markups
Carried Forward
11/08/2022


Based on the Work Description ? Existing Log Office Building will be moved and placed on a new foundation and a new bathroom will be added, The Home Ranch has been operating as a guest ranch since 1978. It has been open to the public since then.there have been revisions to their PUD over the years and they also have associated permits such as horseback riding or cross country ski tours as an amenity to the ranch. Based on the architectural floor plans this appears to be within the maximum occupant load that allows a single or unisex restroom. However, the plans shall include provisions for accessibility, as applicable. Include architectural plans showing accessible route into the ranch headquarters building with dimensions required to verify code requirements of new bathroom and clearances to access from conference room, etc.
See Document Markups
Carried Forward
07/28/2022


Relocation of the historic huts along with many other recently approved projects under the PUD require building permits. Please open permits with architectural and engineering plans with documentation of permits or supporting documents in support of proposed use(s).
Planning Review Approved 08/03/2022 07/27/2022
Michael Fitz ((970) 879-2704)   Send Email
PUD was amended and recorded at Reception #837644. This office building relocation is consistent with that PUD. Scope of review is limited to this building and no other site features are reviewed at this time.

3 Permit Application Submittal 08/05/2022      Status: Pending

Review Type Outcome Est. Completion Date Completed
Environmental Health Review Approved 10/27/2022 10/25/2022
Scott Cowman ((970) 870-5401)   Send Email
Design update received from NWCC and uploaded to this permit.

4 Permit Application Submittal 10/25/2022      Status: Submittal Accepted

Review Type Outcome Est. Completion Date Completed
Building Code Review Approved 11/15/2022 11/09/2022
Ted Allen ((970) 870-5329)   Send Email
See Document Markups
Resolved
11/09/2022


Based on the Work Description ? Existing Log Office Building will be moved and placed on a new foundation and a new bathroom will be added, The Home Ranch has been operating as a guest ranch since 1978. It has been open to the public since then.there have been revisions to their PUD over the years and they also have associated permits such as horseback riding or cross country ski tours as an amenity to the ranch. Based on the architectural floor plans this appears to be within the maximum occupant load that allows a single or unisex restroom. However, the plans shall include provisions for accessibility, as applicable. Include architectural plans showing accessible route into the ranch headquarters building with dimensions required to verify code requirements of new bathroom and clearances to access from conference room, etc.

Fees

Paid Fees Amount Paid Owing Date Paid
Routt County Use Tax Fee $635.00 $635.00 Paid 11/15/2022
Routt County Planning Dept Plan Review Fee $75.00 $75.00 Paid 03/21/2022
Building Permit Fee $1,030.46 $1,030.46 Paid 11/15/2022
Plan Review Fee $669.80 $669.80 Paid 03/21/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Foundation Drain Inspection Pending
Framing Inspection Pending
Roofing Inspection Pending
Drywall Inspection Pending
Grading Inspection Pending
Mike Mordi   Send Email
Final Grading Inspection Pending
Tony Brown ((970) 870-5344)   Send Email
Building Final Inspection Pending
Insulation Inspection Pending
Insulation Inspection Not Ready 11/28/2022 11/28/2022 11/28/2022
Silas Ebbert ((970) 870-5347)   Send Email
Footing Inspection Passed 11/28/2022 11/28/2022 11/28/2022
Ron Norton ((970) 870-5331)   Send Email
Foundation Inspection Passed 11/28/2022
Ron Norton ((970) 870-5331)   Send Email

Conditions

Condition Status Department Category Expiration Date Due Date
Miscellaneous Open GIS Prior to Final Building Inspection