Summary

PRAB220830
Accessory Building
Canceled
BERLET, LUKE & CARISSA (JT)
New
New barn 1 bath/0 bed
06/27/2022
12/24/2022

Locations

Submittals

1 Permit Application Submittal 06/27/2022      Status: Returned for Correction

Review Type Outcome Est. Completion Date Completed
Fire Code Review Approved 07/26/2022 07/28/2022
Brady Glauthier ((970) 736-8104)   Send Email
Public Works Review Approved 07/26/2022 07/25/2022
Tony Brown ((970) 870-5344)   Send Email
GIS Land Development Review Approved 07/26/2022 07/21/2022
Jason Blair ((970) 870-5465)   Send Email
Building Code Review Approved 07/26/2022 07/15/2022
Ted Allen ((970) 870-5329)   Send Email
Garage is heated.
Electrical Review Approved 07/26/2022 07/13/2022
Tom Cook ((970) 870-5339)   Send Email
final approval subject to field inspection
Environmental Health Review Failed 07/26/2022 07/13/2022
Rick Melzer ((970) 870-5588)   Send Email
Miscellaneous
Outstanding
07/13/2022


Failed Two corrections: Separate Routt County Environmental Health Application fee of $700.00 required. Please visit the Routt County website / Environmental Health / Apply for a septic permit / Please call Environmental Health when application is completed, that is how we make the fee payable. Be sure to scroll all the way down to bottom of page for payment. Upload engineered design to Documents and images on your application; this is located in the column on the right https://cityview2.iharriscomputer.com/RouttCountyPortal The submitted Onsite Wastewater Treatment System design needs to show inspection ports at each corner of the bed. The submitted design shows two inspection ports. REGULATION NO. 43 - ON-SITE WASTEWATER TREATMENT SYSTEM REGULATION 5 CCR 1002-43 Section 43.10.F.6 a. A 4-inch inspection port accessible from ground surface must be installed at the terminal end of each lateral in a trench system and at each corner of a bed system. The bottom of the inspection port tube must extend to the infiltrative surface and not be connected to the end of a distribution pipe.
Planning Review Failed 07/26/2022 07/11/2022
Michael Fitz ((970) 879-2704)   Send Email
Miscellaneous
Outstanding
07/11/2022


Plumbing agreement required prior to BP issuance.
Accessory outbuilding (garage) proposed in far SE corner of MRE-zoned parcel in Ski View Estates. Setbacks and height are met. Building contains plumbing, so a Plumbing Agreement shall be required prior to issuance of this permit. Please contact Planning for details.
External Agencies Review Approved 07/26/2022 07/11/2022
Nick Neiberger ((970) 870-5335)   Send Email
Applicant does not require sign off from the Morrison Creek Water and Sanitation District. Approved. Thank you Building permit PRAB220830

2 Permit Application Submittal 07/29/2022      Status: Pending


Fees

Paid Fees Amount Paid Owing Date Paid
Routt County Planning Dept Plan Review Fee $75.00 $75.00 Paid 06/30/2022
Plan Review Fee $581.35 $581.35 Paid 06/30/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

There are no inspections for this permit application.

Conditions

Condition Status Department Category Expiration Date Due Date
Truss Drawings Deferred Submittal Open Prior to Insulaton Inspections Scheduled
: Truss drawings shall be submitted, reviewed and approved prior to installation and inspections.
Final Fire Inspection Required Open Prior to Issuance of TCO/CO/CC
: Final Fire Inspection Required 1. Address sign may be posted on house (if closer than 50' from roadway and is clearly seen from roadway) or posted at the entrance of the roadway. Sign must be aluminum with reflective vinyl for background and lettering. Lettering must be at least 3" in height and white in color. Background must either be green, brown or blue. Sign can be either horizontal or vertical. The installation of the sign must be permanent and able to withstand weather and be high enough off the ground so that it remains visible during winter snow pack. 2. Propane tank (if applicable) must have a grey schedule 40 3/4" PVC pipe permanently mounted at the location of the tanks shutoff valve. Pipe must be long enough to see during winter snow pack. 3. A Oak Creek Fire District lock box must be permanently mounted on either garage side. Lock box must be easily seen and accessible. Lock box must be obtained from one of the local security retailers. If more than one building lock box must be installed for each building.
Design Engineer on-site Wastewater final report Open Environmental Health Prior to Issuance of TCO/CO/CC
: Design Engineer on-site Wastewater final report, including as Built plans.