CityView Portal

Development Permit Application Status

S-21-111


You will only be able to schedule inspections if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

S-21-111
On-Site Wastewater
Issued
HOME RANCH LLC
Work Description: 7 cabins with design flow 1,350 gpd, 9 rooms, 18 people.2,700 gallon septic tank capacity - recommended 1,000, 1,500, and 1,250 gallon concrete tanks. Pump system required to convey effluent from septic tank to dosing tank.A pressurized distribution system and six sand filter treatment area zones each of 284 sq ft. to meet overall requirement of 1,688 sq ft.
02/11/2021
02/11/2021
11/11/2022

Locations

Submittals

There are no submittals for this permit application.

Unlinked Reviews

Review Type Outcome Est. Completion Date Completed
Environmental Health Review Approved 02/11/2021
SysAdmin
VP legacy plan review: Routt Environmental Health

Inspections

There are no inspections for this development permit application.

Conditions

There are no conditions for this development permit application.

Related Permit & Planning Applications

Reference Number Status Type
B-20-799 Expired Addition
M-20-707 Expired Plumbing
M-21-168 Closed Mechanical
E-21-238 Closed Electrical
P-21-217 Closed Plumbing

Documents & Images

Date Uploaded File Type Name
02/11/2021 Legacy Permit Document Application and Design Cabins.pdf
02/11/2021 Legacy Permit Document Site Plan.pdf