CityView Portal

Permit Application Status

PRPO241176


You will only be able to schedule inspections if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRPO241176
Pool/Hot Tub
Permit(s) Issued
HOME RANCH LLC
New
A new, inground swimming pool, hot tub, and small mechanical building to house heaters and pumps. Foundation only 11.04.2024
09/10/2024
11/04/2024
11/04/2027

Locations

Submittals

1 Permit Application Submittal 09/10/2024      Status: Returned for Correction
Review Type Outcome Est. Completion Date Completed
External Agencies Review Approved 10/18/2024 10/18/2024
Building Code Review Failed 10/18/2024 10/16/2024
Public Works Review Approved 10/18/2024 10/14/2024
GIS Land Development Review Approved 10/18/2024 10/14/2024
Planning Review Approved 10/18/2024 10/11/2024

2 Permit Application Submittal 10/18/2024      Status: Pending
Review Type Outcome Est. Completion Date Completed
Environmental Health Review Approved 05/06/2025 04/29/2025
Environmental Health Review Failed 04/25/2025 04/24/2025
Building Code Review Failed 04/25/2025 04/21/2025
Building Code Review Approved 11/11/2024 11/04/2024

Fees

There are no fees for this permit application, or you are not authorized to view them.

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection Pending
Building Final Inspection Pending
Foundation Inspection Pending
Foundation Inspection Partial Pass 11/5/2024 11/5/2024 11/05/2024
Silas Ebbert ((970) 870-5347)   Send Email
Foundation Inspection Not Ready 11/8/2024 11/8/2024 11/08/2024
Silas Ebbert ((970) 870-5347)   Send Email
Foundation Inspection Partial Pass 12/9/2024 12/9/2024 12/09/2024
Silas Ebbert ((970) 870-5347)   Send Email
Foundation Inspection Partial Pass 12/16/2024 12/16/2024 12/16/2024
Silas Ebbert ((970) 870-5347)   Send Email

Conditions

Condition Status Category
Architectural elevations and sections Deferred Submittal Open Prior to Full Building Permit Issuance
Building Services
While this permit was issued for the construction of foundations, the following code compliance items referencing the International Swimming Pool and Spa Code (ISPSC) as referenced per IBC 3109.1 or referenced otherwise will need to be addressed prior to continuing the plan review for full permit: 1. Site built pools and spas shall also have insulation installed around the entire perimeter of all walls below or above grade with an R-value minimum of R-15 as per IECC R403.10.3.1 (Amended New). 2. In climates subject to freezing temperatures, outdoor pool and spa shells and appurtenances, piping, filter systems, pumps and motors, and other components shall be designed and constructed to provide protection from damage from freezing. 307.2.3 Freeze protection. 3. Piping, including process piping, shall be inspected prior to backfilling per 302.4. Also, circulation system piping shall be subjected to a hydrostatic pressure test of 25 pounds per square inch (psi) (172.4 kPa). This pressure shall be held for not less than 15 minutes per 311.9 4. While there are exceptions to indicating the water temperature in the spa, 506.2 requires water temperature controls. 5. Public pools and public pool areas that operate during periods of low illumination shall be provided with emergency lighting that will automatically turn on to permit evacuation of the pool and securing of the area in the event of power failure per 321.3 Emergency illumination. 6. Public facilities shall have a clock that is visible to spa users. 7. The Site Plan needs to show complete details for construction of the pool terrace with accessible route between lodge, pool (with lift) and where ramps and flights of stairways have handrails on each side IBC Chapters 10 and 11). [Ted Allen @ 04/21/2025 3:17 PM]
Miscellaneous Open Prior to Issuance of TCO/CO/CC
Environmental Health
An inspection is required to ensure the final construction complies with the State of Colorado Swimming Pool and Mineral Bath Regulations. Contact Rick Melzer at rmelzer@co.routt.co.us or call (970) 870-5588 to schedule a time and date.

Related Permit & Planning Applications

There are no related items for this permit application.

Documents & Images

Date Uploaded File Type Name
09/10/2024 Report Soil Report
09/10/2024 Receipt Receipt for transaction:2024-001255
09/11/2024 Letter Incomplete Application Notice (Generate/Send Incomplete Application Notice)
10/08/2024 Plans ARCHITECTURAL
10/08/2024 Plans SITE PLAN
10/08/2024 Plans Structural Plans
10/18/2024 Letter Permit Review Corrections Notice (Generate/Send Correction Notice)
11/04/2024 Form Foundation only PRP241176
11/04/2024 Letter Permit - Detailed
11/04/2024 Receipt Receipt for transaction:2024-001659
11/05/2024 Report Inspection Report (Foundation Inspection)
11/08/2024 Report Inspection Report (Foundation Inspection)
12/09/2024 Report Inspection Report (Foundation Inspection)
12/16/2024 Report Inspection Report (Foundation Inspection)
04/18/2025 Plans Home Ranch Pool & Spa (STAMPED 4-8-25) (1)
04/24/2025 Letter Permit Review Corrections Notice