CityView Portal

Permit Application Status

B-16-111


You will only be able to schedule inspections if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

B-16-111
Addition
Closed
ROUTT COUNTY
Addition
Work Description: Metal building addition for District #1 Routt County Road and Bridge Shop (RFP #480) in Oak Creek, Colorado. BedroomsNoEx: 0 BedroomsNoProp: 0 HeightofConstructionEx: 0.00 HeightofConstructionProp: 0.00 LivingAreaEx: 0.00 LivingAreaProp: 0.00 SignLength: 0.00 SignWidth: 0.00 StoriesNoEx: 0 StoriesNoProp: 0 TotalAreaEx: 0.00 TotalAreaProp: 0.00
06/08/2016
06/29/2016
06/29/2019
11/15/2016

Locations

Submittals

There are no submittals for this permit application.

Unlinked Reviews

Review Type Outcome Est. Completion Date Completed
External Agencies Review Approved 06/29/2016
SysAdmin
VP legacy plan review: YVEA
External Agencies Review Approved 06/28/2016
SysAdmin
VP legacy plan review: Atmos Energy
Building Code Review Approved 06/28/2016
SysAdmin
VP legacy plan review: Routt Building sysadmin - Jun 16 2016 2:56PM - has to be an Architectural sheet showing the code analysis and related details. sysadmin - Jun 28 2016 1:07PM - The special inspection shall be conducted by NWCC, Inc. The special inspector shall verify foundation site prep and compaction as required by the engineered foundation plans. The special inspector shall create a report of the special inspection and submit to the Routt County Regional Building Department.
Legacy Permitting Review Approved 06/24/2016
SysAdmin
VP legacy plan review: Z_Legacy Planning Dept. sysadmin - Jun 24 2016 12:02PM - Proposal is for addition to Oak Creek shop. The 100 foot setback to Oak Creek as shown on proposed site plan is shown. Appears to conform to submittal site plan. Per Mary Alice, Town's requirements for building permit stage (some work must be done before CA can be approved) are satisfied.
Electrical Review Approved 06/17/2016
SysAdmin
VP legacy plan review: Routt Electrical Plan Review sysadmin - Jun 17 2016 1:43PM - Electrical is subject to approval at field inspection
Road and Bridge Review Approved 06/16/2016
SysAdmin
VP legacy plan review: Routt Road & Bridge/Engineering
Legacy Permitting Review Approved 06/16/2016
SysAdmin
VP legacy plan review: Oak Creek Fire sysadmin - Jun 16 2016 11:38AM - Lock Box Required sysadmin - Jun 16 2016 11:38AM - Portable Welders must be fitted with Brackets and Fire extingushers sysadmin - Jun 16 2016 11:38AM - $35.00 Permit review fee waived by OCFPD
GIS Land Development Review Approved 06/16/2016
SysAdmin
VP legacy plan review: Routt Addressing/GIS

Fees

Paid Fees Amount Paid Owing Date Paid
Legacy Permitting Fee $1,256.20 $1,256.20 Paid 06/08/2016
Routt County Planning Dept Plan Review Fee $50.00 $50.00 Paid 06/08/2016
Building Permit Fee $1,932.62 $1,932.62 Paid 06/08/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection Complete 08/03/2016
SysAdmin
Legacy Permitting Inspection Complete 08/16/2016
SysAdmin
Footing Inspection Complete 08/23/2016
SysAdmin
Plumbing Rough-in Inspection Complete 08/26/2016
SysAdmin
Footing Inspection Complete 09/06/2016
SysAdmin
Legacy Permitting Inspection Complete 09/19/2016
SysAdmin
Legacy Permitting Inspection Complete 10/12/2016
SysAdmin
Legacy Permitting Inspection Complete 10/18/2016
SysAdmin
Legacy Permitting Inspection Complete 10/21/2016
SysAdmin
Legacy Permitting Inspection Complete 10/21/2016
SysAdmin
Legacy Permitting Inspection Complete 10/26/2016
SysAdmin
Electrical Rough-in Inspection Complete 11/07/2016
SysAdmin
Legacy Permitting Inspection Complete 11/10/2016
SysAdmin
Legacy Permitting Inspection Complete 11/10/2016
SysAdmin
Electrical Final Inspection Complete 11/15/2016
SysAdmin
Building Final Inspection Complete 11/15/2016
SysAdmin

Conditions

There are no conditions for this permit application.

Related Permit & Planning Applications

There are no related items for this permit application.

Documents & Images

Date Uploaded File Type Name
06/08/2016 Legacy Permit Document TPC Routt County Commissioners.pdf
06/08/2016 Legacy Permit Document 1103-015-Site Plan-160523 Final.pdf
06/08/2016 Legacy Permit Document M1-P3 YVE Mechanical.pdf
06/08/2016 Legacy Permit Document Oak Creek Shop - Elec Permit Set 20160516.pdf
06/08/2016 Legacy Permit Document Metal Building for Building Depart ment.pdf
06/08/2016 Legacy Permit Document R_B_ShopFoundation Preliminary AE.pdf
06/08/2016 Legacy Permit Document Contractors Exemption Road and Bridge 001.jpg
06/08/2016 Legacy Permit Document Contractors Exemption Road and Bridge 001.jpg
06/30/2016 Legacy Permit Document B-16-111 merged.pdf
01/14/2019 Legacy Permit Document RFP 480 D1ShopExpansionSoilsReport.pdf