Permit Application Status
PRAB221072
You will only be able to schedule inspections if you are a contact on the permit application.
Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.
Summary
Property Owner's Full Name:
Locations
Submittals
1 Permit Application Submittal 08/04/2022
Status: Returned for Correction
Documents Returned For Corrections
Review Type
Outcome
Est. Completion Date
Completed
Public Works Review
Approved
08/22/2022
08/22/2022
Reviewer:
Reviewer Comments:
External Agencies Review
Approved
08/22/2022
08/22/2022
Reviewer:
Reviewer Comments:
N. Routt Fire - chief@northrouttfire.org
No issues or comments...
Building Code Review
Failed
08/22/2022
08/16/2022
Reviewer:
Corrections:
Correction 1:
Miscellaneous
Comments:
Before the existing lodge building is approved to serve the public for public water closets, lavatories, drinking fountains and service sinks, the kitchen (if applicable) and rest rooms require a change of use from how this facility was last reviewed. Also, the required public facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 500 feet (152 m).
Provide a floor plan to show that total of water closets, lavatories and service sinks that are to be provided to include provisions for accessibility, as applicable. Include architectural plans showing room uses, dimensions required to verify code requirements, accessibility, accessible route, and location on Site Plan as per IBC 2902.3.3. The adopted IPC Section 311.1 finds toilet facilities of the nonsewer type shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Family or assisted-use toilet and bathing rooms shall be located on an accessible route as applicable.
Correction 2:
Miscellaneous
Comments:
The engineer in responsible charge of the design shall verify in writing if special inspection is required by IBC Section 1704 to include masonry walls. The inspection program shall designate the portions of the work that require special inspection and the name or names of the individuals or firms who are to perform the special inspections, and indicate the duties of the special inspectors. Special inspectors shall be employed by the owner, the architect or engineer responsible for the design, or an agent of the owner, but NOT by the contractor or any other person responsible for the work. Provide the name or names of the individuals or firms who are to perform the special inspections.
Reviewer Comments:
GIS Land Development Review
Approved
08/22/2022
08/11/2022
Reviewer:
Reviewer Comments:
Unique address is not required for pavilion. Proposed structure is located adjacent to existing cabin with the address: 27315 Home Ranch Rd Unit J. Address and Parcel # have been updated on permit to show nearest existing address.
Environmental Health Review
Failed
08/22/2022
08/11/2022
Reviewer:
Reviewer Comments:
Facility plans indicate restrooms and a kitchen which require wastewater disposal to an onsite wastewater treatment system. Application materials and fees are located here: https://cityview2.iharriscomputer.com/RouttCountyPortal
Planning Review
Approved
08/22/2022
08/08/2022
Reviewer:
Reviewer Comments:
Open-air pavilion proposed on Home Ranch parcel. Pavilion is consistent with PUD plan recorded at Reception #837644.
2 Permit Application Submittal 08/22/2022
Status: Returned for Correction
Review Type
Outcome
Est. Completion Date
Completed
Environmental Health Review
Failed
08/30/2022
09/02/2022
Reviewer:
Reviewer Comments:
Building Code Review
Failed
08/30/2022
08/26/2022
Reviewer:
Corrections:
Correction 1:
Miscellaneous
Comments:
Before the existing lodge building is approved to serve the public for public water closets, lavatories, drinking fountains and service sinks, the kitchen (if applicable) and rest rooms require a change of use from how this facility was last reviewed. Also, the required public facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 500 feet (152 m).
Provide a floor plan to show that total of water closets, lavatories and service sinks that are to be provided to include provisions for accessibility, as applicable. Include architectural plans showing room uses, dimensions required to verify code requirements, accessibility, accessible route, and location on Site Plan as per IBC 2902.3.3. The adopted IPC Section 311.1 finds toilet facilities of the nonsewer type shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Family or assisted-use toilet and bathing rooms shall be located on an accessible route as applicable. UNRESOLVED. However RCRBD is authorized to accept proposed modifications and alternative methods of construction where the strict letter of the code is impractical and the modification or alternative method is in compliance with the intent and purpose of the code, alternative materials, designs and methods not specifically addressed in the code can be approved by the building official where the proposed materials, designs or methods comply with the intent of the provisions of the code (see Section 104.11).
Correction 2:
Miscellaneous
Comments:
The engineer in responsible charge of the design shall verify in writing if special inspection is required by IBC Section 1704 to include masonry walls. The inspection program shall designate the portions of the work that require special inspection and the name or names of the individuals or firms who are to perform the special inspections, and indicate the duties of the special inspectors. Special inspectors shall be employed by the owner, the architect or engineer responsible for the design, or an agent of the owner, but NOT by the contractor or any other person responsible for the work. Provide the name or names of the individuals or firms who are to perform the special inspections. UNRESOLVED. Please submit the special inspection program as requested.
Reviewer Comments:
3 Permit Application Submittal 09/06/2022
Status: Returned for Correction
Review Type
Outcome
Est. Completion Date
Completed
Building Code Review
Failed
09/13/2022
09/07/2022
Reviewer:
Corrections:
Correction 1:
Miscellaneous
Comments:
Before the existing lodge building is approved to serve the public for public water closets, lavatories, drinking fountains and service sinks, the kitchen (if applicable) and rest rooms require a change of use from how this facility was last reviewed. Also, the required public facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 500 feet (152 m).
Provide a floor plan to show that total of water closets, lavatories and service sinks that are to be provided to include provisions for accessibility, as applicable. Include architectural plans showing room uses, dimensions required to verify code requirements, accessibility, accessible route, and location on Site Plan as per IBC 2902.3.3. The adopted IPC Section 311.1 finds toilet facilities of the nonsewer type shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Family or assisted-use toilet and bathing rooms shall be located on an accessible route as applicable. UNRESOLVED. However RCRBD is authorized to accept proposed modifications and alternative methods of construction where the strict letter of the code is impractical and the modification or alternative method is in compliance with the intent and purpose of the code, alternative materials, designs and methods not specifically addressed in the code can be approved by the building official where the proposed materials, designs or methods comply with the intent of the provisions of the code (see Section 104.11).
Correction 2:
Miscellaneous
Comments:
The engineer in responsible charge of the design shall verify in writing if special inspection is required by IBC Section 1704 to include masonry walls. The inspection program shall designate the portions of the work that require special inspection and the name or names of the individuals or firms who are to perform the special inspections, and indicate the duties of the special inspectors. Special inspectors shall be employed by the owner, the architect or engineer responsible for the design, or an agent of the owner, but NOT by the contractor or any other person responsible for the work. Provide the name or names of the individuals or firms who are to perform the special inspections. UNRESOLVED. Please submit the special inspection program as requested.
Reviewer Comments:
Environmental Health Review
Approved
09/13/2022
09/06/2022
Reviewer:
Reviewer Comments:
ACCORDING TO THE LETTER SENT BY SNAKE RIVER CONSTRUCTION THE PAVILLION WILL NOT HAVE RESTROOMS PORT O POTTIES WILL BE BROUGHT IN FOR EVNETS. THIS APPROVAL DOES NOT NEGATE THE FAILED REVIEW FOR PRAB220245 THE BATHROOM BUILDING APPLICATION. FURTHER INFORMATION IS REQUIRED FOR THIS PROJECT
4 Permit Application Submittal 09/08/2022
Status: Submittal Accepted
Review Type
Outcome
Est. Completion Date
Completed
Building Code Review
Approved
10/27/2022
10/21/2022
Reviewer:
Reviewer Comments:
Addendum 10.20.22
Building Code Review
Approved
09/19/2022
09/15/2022
Reviewer:
Corrections:
Correction 1:
Miscellaneous
Comments:
The engineer in responsible charge of the design shall verify in writing if special inspection is required by IBC Section 1704 to include masonry walls. The inspection program shall designate the portions of the work that require special inspection and the name or names of the individuals or firms who are to perform the special inspections, and indicate the duties of the special inspectors. Special inspectors shall be employed by the owner, the architect or engineer responsible for the design, or an agent of the owner, but NOT by the contractor or any other person responsible for the work. Provide the name or names of the individuals or firms who are to perform the special inspections. UNRESOLVED. Please submit the special inspection program as requested.
Reviewer Comments:
Fees
There are no fees for this permit application, or you are not authorized to view them.
Inspections
Inspection
Outcome
Requested
Scheduled
Date Inspected
Foundation Drain Inspection
Pending
Inspector:
Roofing Inspection
Pending
Inspector:
Insulation Inspection
Pending
Inspector:
Drywall Inspection
Pending
Inspector:
Grading Inspection
Pending
Inspector:
Mike Mordi
Send Email
Final Grading Inspection
Pending
Inspector:
Tony Brown
((970) 870-5344)
Send Email
Building Final Inspection
Pending
Inspector:
Footing Inspection
Pending
Inspector:
Framing Inspection
Pending
Inspector:
Footing Inspection
Not Ready
10/7/2022
10/10/2022
10/10/2022
Inspector:
Silas Ebbert
((970) 870-5347)
Send Email
Footing Inspection
Passed
10/11/2022 (AM)
10/12/2022
10/12/2022
Inspector:
Silas Ebbert
((970) 870-5347)
Send Email
Foundation Inspection
Passed
10/18/2022
10/17/2022
10/18/2022
Inspector:
Silas Ebbert
((970) 870-5347)
Send Email
Framing Inspection
Partial Pass
9/12/2023
9/12/2023
09/12/2023
Inspector:
Ron Norton
((970) 870-5331)
Send Email
Conditions
Condition
Status
Category
Miscellaneous
Open
Prior to Final Building Inspection
Related Permit & Planning Applications
Reference Number
Status
Type
PRPL231195
Permit(s) Issued
Plumbing
PREL231209
Permit(s) Issued
Electrical