Permit Application Status

PRAD210132


You will only be able to schedule inspections if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRAD210132
Addition
Permit(s) Issued
HOME RANCH LLC
Addition
Alteration and addition to existing lodge.
08/30/2021
07/20/2023

Locations

Submittals

1 Permit Application Submittal 08/30/2021      Status: Returned for Correction

Review Type Outcome Est. Completion Date Completed
Planning Review TCO Approved 09/10/2021 09/27/2021
Chris Brookshire ((970) 879-2704)   Send Email
Building application plans for the lodge are not as approved under the PUD. Any changes to the PUD are reviewed under Section 7.4 of the RCZR. Revisions need to be submitted/reviewed to determine process for an amendment to the PUD.
External Agencies Review Approved 09/10/2021 09/21/2021
Malea Michael-Ferrier ((970) 870-5334)   Send Email
N. Routt Fire - chief@northrouttfire.org No issues or concerns with this set of plans for the project. MS
Environmental Health Review TCO Approved 09/10/2021 09/17/2021
Amanda Williams ((970) 870-5588)   Send Email
Miscellaneous
Carried Forward
02/01/2022


Failed review status: Awaiting application submittal and $600.00 associated fee. Please go to City View Portal fill out and submit application and pay fee.
Application and fee required ($600.00). Please submit directly to Routt County Environmental Health. via the City View Portal http://www.co.routt.co.us/163/On-Site-Wastewater OWTS design received and uploaded
GIS Land Development Review Approved 09/10/2021 09/15/2021
Jason Blair ((970) 870-5465)   Send Email
Miscellaneous
Outstanding
09/15/2021


The Home Ranch will require an addressing review prior to CO approval. Sub-address unit numbers are required on all occupied structures to be in compliance with Routt County Addressing Requirements. New addresses will be assigned by Routt County GIS and owner is responsible for installation of signage prior to CO, or approval of future permit applications.
The Home Ranch will require an addressing review prior to CO approval. Sub-address unit numbers are required on all occupied structures to be in compliance with Routt County Addressing Requirements. New addresses will be assigned by Routt County GIS and owner is responsible for installation of signage prior to CO, or approval of future permit applications.
Building Code Review TCO Approved 09/10/2021 09/10/2021
Ted Allen ((970) 870-5329)   Send Email
See Document Markups
Carried Forward
02/01/2022


While the Home Ranch is now operating as a private familyranch and CLOSED TO THE PUBLIC, we wish to understandthe replacement of the nearly 10,000-square-footlodge/bed-and-breakfast. The following code analysis information is required on allcommercial plans to the Routt County Regional BuildingDepartment for review and approval, if applicable:1. Type of Construction IBC Chapter 62. Occupancy Classification IBC Chapter 3 3. Actual Area/Allowable Area IBC 504 and Table 503Square foot breakdown for each individual useInclude allowable calculations per IBC 506Include mixed occupancy calculations per IBC 302.3, ifapplicable4. Actual Height/Allowable Height IBC 503, 504 and Table5035. Actual Stories/Allowable stories IBC 503, 506 and Table5036. Occupant Load (each individual use) IBC 1004 and Table1004.1.27. Exits Required/Exits Provided IBC 1013 and Table1004.1.28. Accessibility IBC 1105 and Table 1108.39. Fire resistance of exterior walls and openings due to fireseparation distance IBC TABLE 601 AND 602 and Sections704, 705, 706, 715 10. Fire resistive construction requirements, IBC Chapter 6Provide a table specific to the project Otherwise, due to ICC Codes not adequately addressingVRBO?s or Vacation Home Rentals that are (Transient)Environments, RCRBD has developed similar policy we canuse to review both new construction and/or Existing Buildingsundergoing a Change of Occupancy (as applicable).
See Document Markups
Carried Forward
02/01/2022


All construction shall comply with the 2018 local code amendments as shown on approved plans. Energy provisions from the International Energy Conservation Code—Residential Provisions applicable to residential buildings which fall under the scope of this code are shown in the attached checklist. The plans need to show this information. A building section cut or typical wall section through the representative wall and floors as required to show the thermal envelope as required to accurately show in detail shall be submitted (include location of all building and section cuts on the plans). All information shall be using Zone 7, Dry. Details shall include, but are not limited to, as applicable: 1. Insulation materials and their R-values (include per inch). 2. Fenestration U-factors and air leakage. 3. Area-weighted U-factor calculations (if applicable). 4. Mechanical system design criteria (if applicable). Specify method and type of heat. 5. Equipment and system controls. 6. Duct sealing, duct and pipe insulation and location. 7. Air sealing details. 8. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding three air changes per hour.
See Document Markups
Carried Forward
02/01/2022


Masonry fireplaces shall be constructed in accordance with the applicable provisions of MASONRY FIREPLACES. Wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air.
See Document Markups
Carried Forward
02/01/2022


Provide specifications for kitchen equipment, commercial grade or domestic would help.
See Document Markups
Carried Forward
02/01/2022


Provide details of fireplace, type of fuel, construction, etc.
See Document Markups
Carried Forward
02/01/2022


See Document Markups
Carried Forward
02/01/2022


Regardless of mezzanine designation, the home ranch suite makes this the third floor.
See Document Markups
Carried Forward
02/01/2022


The Hawk's Nest makes this a 3-Story structure.
See Document Markups
Carried Forward
02/01/2022


Provide details of item in center of room and room use(s).
See Document Markups
Carried Forward
02/01/2022


A COMPLETE SET OF PLANS SUITABLE FOR REVIEW, SHOULD INCLUDE: Building Sections and Details. Architectural building sections and details shall include the following information:Foundation details. (tie-downs)Existing and proposed grade to include relationship between finished floor elevation and existing grade. Existing and finish grade at foundation for each elevation. Interior wall and ceiling finishes. (drywall, paneling, etc.)Exterior wall finishes. Exterior walls shall provide the building with a waterproof foundation or weather resistant exterior wall envelopewhere applicable. Routt County inspectors report non-compliant backfilling above masonry weepholes against woodframing. Masonry veneer shall be installed in accordance with applicable wall covering, sealant, flashing andweepholes, water-resistive barrier, metal ties, 1-in. air space, steel lintels over all openings and specify steel lintelsto support veneer and over all openings as applicable. Adhered masonry veneer shall comply with the applicable requirements in IBC Section 1405.10.1 and Sections 6.1and 6.3 of TMS 402/ACI 530/ASCE 5. RCRBD finds these requirements to be similar to cement plaster (stucco)applied to exterior walls and shall conform to similar requirements specified in Chapter 25. Commentary FigureR703.6 (3) (see attached) illustrates a similar drainage system to include a weep screed at the bottom of exteriorwalls to permit the moisture to escape to the exterior of the building. Provide details for locations of vapor retarders,include a continuous weep screed at the bottom of cultured stone (similar to stucco walls) to permit the moisture toescape to the exterior of the building. Also include specification of moisture barrier, as applicable to veneer used. Roofing details. (underlayments and roof covering materials)Stairway construction details (material specifications, handrails) Guardrail construction details. (material specifications, guardrail height, spacing of intermediate rails)
See Document Markups
Carried Forward
02/01/2022


Eliminate all gaps in insulation or trade using COMcheck.

2 Permit Application Submittal 09/29/2021      Status: Pending

Review Type Outcome Est. Completion Date Completed
Building Code Review Approved 07/18/2023 07/19/2023
Ted Allen ((970) 870-5329)   Send Email
Miscellaneous
Outstanding
07/11/2023


A. While the Home Ranch is now operating as a private familyranch and CLOSED TO THE PUBLIC, we wish to understandthe replacement of the nearly 10,000-square-footlodge/bed-and-breakfast. The following code analysis information is required on allcommercial plans to the Routt County Regional BuildingDepartment for review and approval, if applicable:1. Type of Construction IBC Chapter 62. Occupancy Classification IBC Chapter 3 3. Actual Area/Allowable Area IBC 504 and Table 503Square foot breakdown for each individual useInclude allowable calculations per IBC 506Include mixed occupancy calculations per IBC 302.3, ifapplicable4. Actual Height/Allowable Height IBC 503, 504 and Table5035. Actual Stories/Allowable stories IBC 503, 506 and Table5036. Occupant Load (each individual use) IBC 1004 and Table1004.1.27. Exits Required/Exits Provided IBC 1013 and Table1004.1.28. Accessibility IBC 1105 and Table 1108.39. Fire resistance of exterior walls and openings due to fireseparation distance IBC TABLE 601 AND 602 and Sections704, 705, 706, 715 10. Fire resistive construction requirements, IBC Chapter 6Provide a table specific to the project Otherwise, due to ICC Codes not adequately addressingVRBO?s or Vacation Home Rentals that are (Transient)Environments, RCRBD has developed similar policy we canuse to review both new construction and/or Existing Buildingsundergoing a Change of Occupancy (as applicable). Todd Carr, Building Official has already approved RESOLVED B. All construction shall comply with the 2018 local code amendments as shown on approved plans. Energy provisions from the International Energy Conservation Code—Residential Provisions applicable to residential buildings which fall under the scope of this code are shown in the attached checklist. The plans need to show this information. A building section cut or typical wall section through the representative wall and floors as required to show the thermal envelope as required to accurately show in detail shall be submitted (include location of all building and section cuts on the plans). All information shall be using Zone 7, Dry. Details shall include, but are not limited to, as applicable: RESOLVED 1. Insulation materials and their R-values (include per inch). 2. Fenestration U-factors and air leakage. 3. Area-weighted U-factor calculations (if applicable). 4. Mechanical system design criteria (if applicable). While heat-loss calculations show 400 kBtu Boiler, Specify location and manufacturer sepecs. 5. Equipment and system controls. 6. Duct sealing, duct and pipe insulation and location, if applicable. 7. Air sealing details C. Masonry veneer shall be installed in accordance with Table R703.8.4(1) with stud backing. As an alternative to the airspace required by Table R703.8.4, grout shall be permitted to fill the airspace as shown in some sections on S-1.4. Call-out backing, whether wood, steel or masonry (firebrick not considered structural) and show wall covering, sealant, flashing and weepholes, water-resistive barrier, metal ties, 1-in. air space, steel lintels to support veneer and over all openings and roof as applicable.RESOLVED D. All plans prepared by registered design professionals submitted to RCRBD for permit shall be signed, sealed and dated as provided by Colorado State Law. RESOLVED E. Provide letter of Special Inspections documenting required special inspections and tests, and correction of any discrepancies noted in the inspections or tests to date (or Final). OUTSTANDING
Helical pier reportsThe above referenced application appears satisfactory with the map of attached Helical pier reports.
Building Code Review Failed 06/29/2023 06/22/2023
Ted Allen ((970) 870-5329)   Send Email
Miscellaneous
Carried Forward
07/11/2023


A. While the Home Ranch is now operating as a private familyranch and CLOSED TO THE PUBLIC, we wish to understandthe replacement of the nearly 10,000-square-footlodge/bed-and-breakfast. The following code analysis information is required on allcommercial plans to the Routt County Regional BuildingDepartment for review and approval, if applicable:1. Type of Construction IBC Chapter 62. Occupancy Classification IBC Chapter 3 3. Actual Area/Allowable Area IBC 504 and Table 503Square foot breakdown for each individual useInclude allowable calculations per IBC 506Include mixed occupancy calculations per IBC 302.3, ifapplicable4. Actual Height/Allowable Height IBC 503, 504 and Table5035. Actual Stories/Allowable stories IBC 503, 506 and Table5036. Occupant Load (each individual use) IBC 1004 and Table1004.1.27. Exits Required/Exits Provided IBC 1013 and Table1004.1.28. Accessibility IBC 1105 and Table 1108.39. Fire resistance of exterior walls and openings due to fireseparation distance IBC TABLE 601 AND 602 and Sections704, 705, 706, 715 10. Fire resistive construction requirements, IBC Chapter 6Provide a table specific to the project Otherwise, due to ICC Codes not adequately addressingVRBO?s or Vacation Home Rentals that are (Transient)Environments, RCRBD has developed similar policy we canuse to review both new construction and/or Existing Buildingsundergoing a Change of Occupancy (as applicable). Todd Carr, Building Official has already approved RESOLVED B. All construction shall comply with the 2018 local code amendments as shown on approved plans. Energy provisions from the International Energy Conservation Code—Residential Provisions applicable to residential buildings which fall under the scope of this code are shown in the attached checklist. The plans need to show this information. A building section cut or typical wall section through the representative wall and floors as required to show the thermal envelope as required to accurately show in detail shall be submitted (include location of all building and section cuts on the plans). All information shall be using Zone 7, Dry. Details shall include, but are not limited to, as applicable: RESOLVED 1. Insulation materials and their R-values (include per inch). 2. Fenestration U-factors and air leakage. 3. Area-weighted U-factor calculations (if applicable). 4. Mechanical system design criteria (if applicable). While heat-loss calculations show 400 kBtu Boiler, Specify location and manufacturer sepecs. 5. Equipment and system controls. 6. Duct sealing, duct and pipe insulation and location, if applicable. 7. Air sealing details C. Masonry veneer shall be installed in accordance with Table R703.8.4(1) with stud backing. As an alternative to the airspace required by Table R703.8.4, grout shall be permitted to fill the airspace as shown in some sections on S-1.4. Call-out backing, whether wood, steel or masonry (firebrick not considered structural) and show wall covering, sealant, flashing and weepholes, water-resistive barrier, metal ties, 1-in. air space, steel lintels to support veneer and over all openings and roof as applicable.RESOLVED D. All plans prepared by registered design professionals submitted to RCRBD for permit shall be signed, sealed and dated as provided by Colorado State Law. RESOLVED E. Provide letter of Special Inspections documenting required special inspections and tests, and correction of any discrepancies noted in the inspections or tests to date (or Final). OUTSTANDING
Resubmittal for full permit issuance
Building Code Review Failed 06/21/2023 06/16/2023
Ted Allen ((970) 870-5329)   Send Email
Miscellaneous
Carried Forward
06/22/2023


A. While the Home Ranch is now operating as a private familyranch and CLOSED TO THE PUBLIC, we wish to understandthe replacement of the nearly 10,000-square-footlodge/bed-and-breakfast. The following code analysis information is required on allcommercial plans to the Routt County Regional BuildingDepartment for review and approval, if applicable:1. Type of Construction IBC Chapter 62. Occupancy Classification IBC Chapter 3 3. Actual Area/Allowable Area IBC 504 and Table 503Square foot breakdown for each individual useInclude allowable calculations per IBC 506Include mixed occupancy calculations per IBC 302.3, ifapplicable4. Actual Height/Allowable Height IBC 503, 504 and Table5035. Actual Stories/Allowable stories IBC 503, 506 and Table5036. Occupant Load (each individual use) IBC 1004 and Table1004.1.27. Exits Required/Exits Provided IBC 1013 and Table1004.1.28. Accessibility IBC 1105 and Table 1108.39. Fire resistance of exterior walls and openings due to fireseparation distance IBC TABLE 601 AND 602 and Sections704, 705, 706, 715 10. Fire resistive construction requirements, IBC Chapter 6Provide a table specific to the project Otherwise, due to ICC Codes not adequately addressingVRBO?s or Vacation Home Rentals that are (Transient)Environments, RCRBD has developed similar policy we canuse to review both new construction and/or Existing Buildingsundergoing a Change of Occupancy (as applicable). Todd Carr, Building Official has already approved RESOLVED B. All construction shall comply with the 2018 local code amendments as shown on approved plans. Energy provisions from the International Energy Conservation Code—Residential Provisions applicable to residential buildings which fall under the scope of this code are shown in the attached checklist. The plans need to show this information. A building section cut or typical wall section through the representative wall and floors as required to show the thermal envelope as required to accurately show in detail shall be submitted (include location of all building and section cuts on the plans). All information shall be using Zone 7, Dry. Details shall include, but are not limited to, as applicable: OUTSTANDING 1. Insulation materials and their R-values (include per inch). 2. Fenestration U-factors and air leakage. 3. Area-weighted U-factor calculations (if applicable). 4. Mechanical system design criteria (if applicable). While heat-loss calculations show 400 kBtu Boiler, Specify location and manufacturer sepecs. 5. Equipment and system controls. 6. Duct sealing, duct and pipe insulation and location, if applicable. 7. Air sealing details C. Masonry veneer shall be installed in accordance with Table R703.8.4(1) with stud backing. As an alternative to the airspace required by Table R703.8.4, grout shall be permitted to fill the airspace as shown in some sections on S-1.4. Call-out backing, whether wood, steel or masonry (firebrick not considered structural) and show wall covering, sealant, flashing and weepholes, water-resistive barrier, metal ties, 1-in. air space, steel lintels to support veneer and over all openings and roof as applicable. D. All plans prepared by registered design professionals submitted to RCRBD for permit shall be signed, sealed and dated as provided by Colorado State Law. E. Provide letter of Special Inspections documenting required special inspections and tests, and correction of any discrepancies noted in the inspections or tests to date (or Final).
Submittal for full permit issuance
Planning Review Approved 06/21/2023 06/15/2023
Michael Fitz ((970) 879-2704)   Send Email
Submittal for full permit issuance Chris Brookshire has already approved without any notes specific to foundation-only, so Planning is OK with this.
Planning Review Approved 02/08/2022 02/14/2022
Alan Goldich ((970) 879-2704)   Send Email
Environmental Health Review Approved 02/08/2022 02/09/2022
Scott Cowman ((970) 870-5401)   Send Email
Miscellaneous
Resolved
02/09/2022


Failed review status: Awaiting application submittal and $600.00 associated fee. Please go to City View Portal fill out and submit application and pay fee.
Miscellaneous
Outstanding
02/09/2022


Conversation with Tim Travis of NWCC on 2/8/2022 and with General Contractor Paul Stoll on 2/9/2022. There are some changes in construction plans compared to what was submitted originally to develop appropriately sized septic designs. According to Tim and Paul, none of the construction changes would result in changes to either of the approved systems. NWCC should submit as-builts that reflect any changes to original plans and ensure that the installed systems are properly sized for the use in order for this office to approve for a C.O.
Conversation with Tim Travis of NWCC on 2/8/2022 and with General Contractor Paul Stoll on 2/9/2022. There are some changes in construction plans compared to what was submitted originally to develop appropriately sized septic designs. According to Tim and Paul, none of the construction changes would result in changes to either of the approved systems. NWCC should submit as-builts that reflect any changes to original plans and ensure that the installed systems are properly sized for the use in order for this office to approve for a C.O.
Building Code Review Approved 02/08/2022 02/02/2022
Ted Allen ((970) 870-5329)   Send Email
See Document Markups
Outstanding
02/01/2022


While the Home Ranch is now operating as a private familyranch and CLOSED TO THE PUBLIC, we wish to understandthe replacement of the nearly 10,000-square-footlodge/bed-and-breakfast. The following code analysis information is required on allcommercial plans to the Routt County Regional BuildingDepartment for review and approval, if applicable:1. Type of Construction IBC Chapter 62. Occupancy Classification IBC Chapter 3 3. Actual Area/Allowable Area IBC 504 and Table 503Square foot breakdown for each individual useInclude allowable calculations per IBC 506Include mixed occupancy calculations per IBC 302.3, ifapplicable4. Actual Height/Allowable Height IBC 503, 504 and Table5035. Actual Stories/Allowable stories IBC 503, 506 and Table5036. Occupant Load (each individual use) IBC 1004 and Table1004.1.27. Exits Required/Exits Provided IBC 1013 and Table1004.1.28. Accessibility IBC 1105 and Table 1108.39. Fire resistance of exterior walls and openings due to fireseparation distance IBC TABLE 601 AND 602 and Sections704, 705, 706, 715 10. Fire resistive construction requirements, IBC Chapter 6Provide a table specific to the project Otherwise, due to ICC Codes not adequately addressingVRBO?s or Vacation Home Rentals that are (Transient)Environments, RCRBD has developed similar policy we canuse to review both new construction and/or Existing Buildingsundergoing a Change of Occupancy (as applicable).
See Document Markups
Outstanding
02/01/2022


All construction shall comply with the 2018 local code amendments as shown on approved plans. Energy provisions from the International Energy Conservation Code—Residential Provisions applicable to residential buildings which fall under the scope of this code are shown in the attached checklist. The plans need to show this information. A building section cut or typical wall section through the representative wall and floors as required to show the thermal envelope as required to accurately show in detail shall be submitted (include location of all building and section cuts on the plans). All information shall be using Zone 7, Dry. Details shall include, but are not limited to, as applicable: 1. Insulation materials and their R-values (include per inch). 2. Fenestration U-factors and air leakage. 3. Area-weighted U-factor calculations (if applicable). 4. Mechanical system design criteria (if applicable). Specify method and type of heat. 5. Equipment and system controls. 6. Duct sealing, duct and pipe insulation and location. 7. Air sealing details. 8. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding three air changes per hour.
See Document Markups
Outstanding
02/01/2022


Masonry fireplaces shall be constructed in accordance with the applicable provisions of MASONRY FIREPLACES. Wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air.
See Document Markups
Outstanding
02/01/2022


Provide specifications for kitchen equipment, commercial grade or domestic would help.
See Document Markups
Outstanding
02/01/2022


Provide details of fireplace, type of fuel, construction, etc.
See Document Markups
Outstanding
02/01/2022


See Document Markups
See Document Markups
Outstanding
02/01/2022


Regardless of mezzanine designation, the home ranch suite makes this the third floor.
See Document Markups
Outstanding
02/01/2022


The Hawk's Nest makes this a 3-Story structure.
See Document Markups
Outstanding
02/01/2022


Provide details of item in center of room and room use(s).
See Document Markups
Outstanding
02/01/2022


A COMPLETE SET OF PLANS SUITABLE FOR REVIEW, SHOULD INCLUDE: Building Sections and Details. Architectural building sections and details shall include the following information:Foundation details. (tie-downs)Existing and proposed grade to include relationship between finished floor elevation and existing grade. Existing and finish grade at foundation for each elevation. Interior wall and ceiling finishes. (drywall, paneling, etc.)Exterior wall finishes. Exterior walls shall provide the building with a waterproof foundation or weather resistant exterior wall envelopewhere applicable. Routt County inspectors report non-compliant backfilling above masonry weepholes against woodframing. Masonry veneer shall be installed in accordance with applicable wall covering, sealant, flashing andweepholes, water-resistive barrier, metal ties, 1-in. air space, steel lintels over all openings and specify steel lintelsto support veneer and over all openings as applicable. Adhered masonry veneer shall comply with the applicable requirements in IBC Section 1405.10.1 and Sections 6.1and 6.3 of TMS 402/ACI 530/ASCE 5. RCRBD finds these requirements to be similar to cement plaster (stucco)applied to exterior walls and shall conform to similar requirements specified in Chapter 25. Commentary FigureR703.6 (3) (see attached) illustrates a similar drainage system to include a weep screed at the bottom of exteriorwalls to permit the moisture to escape to the exterior of the building. Provide details for locations of vapor retarders,include a continuous weep screed at the bottom of cultured stone (similar to stucco walls) to permit the moisture toescape to the exterior of the building. Also include specification of moisture barrier, as applicable to veneer used. Roofing details. (underlayments and roof covering materials)Stairway construction details (material specifications, handrails) Guardrail construction details. (material specifications, guardrail height, spacing of intermediate rails)
See Document Markups
Outstanding
02/01/2022


Eliminate all gaps in insulation or trade using COMcheck.
F/O conditions approval approval until document mark-ups are answered.
Planning Review TCO Approved 09/10/2021 09/27/2021
Chris Brookshire ((970) 879-2704)   Send Email
Building application plans for the lodge are not as approved under the PUD. Any changes to the PUD are reviewed under Section 7.4 of the RCZR. Revisions need to be submitted/reviewed to determine process for an amendment to the PUD.
External Agencies Review Approved 09/10/2021 09/21/2021
Malea Michael-Ferrier ((970) 870-5334)   Send Email
N. Routt Fire - chief@northrouttfire.org No issues or concerns with this set of plans for the project. MS
Environmental Health Review TCO Approved 09/10/2021 09/17/2021
Amanda Williams ((970) 870-5588)   Send Email
Miscellaneous
Carried Forward
02/01/2022


Failed review status: Awaiting application submittal and $600.00 associated fee. Please go to City View Portal fill out and submit application and pay fee.
Application and fee required ($600.00). Please submit directly to Routt County Environmental Health. via the City View Portal http://www.co.routt.co.us/163/On-Site-Wastewater OWTS design received and uploaded
GIS Land Development Review Approved 09/10/2021 09/15/2021
Jason Blair ((970) 870-5465)   Send Email
Miscellaneous
Outstanding
09/15/2021


The Home Ranch will require an addressing review prior to CO approval. Sub-address unit numbers are required on all occupied structures to be in compliance with Routt County Addressing Requirements. New addresses will be assigned by Routt County GIS and owner is responsible for installation of signage prior to CO, or approval of future permit applications.
The Home Ranch will require an addressing review prior to CO approval. Sub-address unit numbers are required on all occupied structures to be in compliance with Routt County Addressing Requirements. New addresses will be assigned by Routt County GIS and owner is responsible for installation of signage prior to CO, or approval of future permit applications.
Building Code Review TCO Approved 09/10/2021 09/10/2021
Ted Allen ((970) 870-5329)   Send Email
See Document Markups
Carried Forward
02/01/2022


While the Home Ranch is now operating as a private familyranch and CLOSED TO THE PUBLIC, we wish to understandthe replacement of the nearly 10,000-square-footlodge/bed-and-breakfast. The following code analysis information is required on allcommercial plans to the Routt County Regional BuildingDepartment for review and approval, if applicable:1. Type of Construction IBC Chapter 62. Occupancy Classification IBC Chapter 3 3. Actual Area/Allowable Area IBC 504 and Table 503Square foot breakdown for each individual useInclude allowable calculations per IBC 506Include mixed occupancy calculations per IBC 302.3, ifapplicable4. Actual Height/Allowable Height IBC 503, 504 and Table5035. Actual Stories/Allowable stories IBC 503, 506 and Table5036. Occupant Load (each individual use) IBC 1004 and Table1004.1.27. Exits Required/Exits Provided IBC 1013 and Table1004.1.28. Accessibility IBC 1105 and Table 1108.39. Fire resistance of exterior walls and openings due to fireseparation distance IBC TABLE 601 AND 602 and Sections704, 705, 706, 715 10. Fire resistive construction requirements, IBC Chapter 6Provide a table specific to the project Otherwise, due to ICC Codes not adequately addressingVRBO?s or Vacation Home Rentals that are (Transient)Environments, RCRBD has developed similar policy we canuse to review both new construction and/or Existing Buildingsundergoing a Change of Occupancy (as applicable).
See Document Markups
Carried Forward
02/01/2022


All construction shall comply with the 2018 local code amendments as shown on approved plans. Energy provisions from the International Energy Conservation Code—Residential Provisions applicable to residential buildings which fall under the scope of this code are shown in the attached checklist. The plans need to show this information. A building section cut or typical wall section through the representative wall and floors as required to show the thermal envelope as required to accurately show in detail shall be submitted (include location of all building and section cuts on the plans). All information shall be using Zone 7, Dry. Details shall include, but are not limited to, as applicable: 1. Insulation materials and their R-values (include per inch). 2. Fenestration U-factors and air leakage. 3. Area-weighted U-factor calculations (if applicable). 4. Mechanical system design criteria (if applicable). Specify method and type of heat. 5. Equipment and system controls. 6. Duct sealing, duct and pipe insulation and location. 7. Air sealing details. 8. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding three air changes per hour.
See Document Markups
Carried Forward
02/01/2022


Masonry fireplaces shall be constructed in accordance with the applicable provisions of MASONRY FIREPLACES. Wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air.
See Document Markups
Carried Forward
02/01/2022


Provide specifications for kitchen equipment, commercial grade or domestic would help.
See Document Markups
Carried Forward
02/01/2022


Provide details of fireplace, type of fuel, construction, etc.
See Document Markups
Carried Forward
02/01/2022


See Document Markups
Carried Forward
02/01/2022


Regardless of mezzanine designation, the home ranch suite makes this the third floor.
See Document Markups
Carried Forward
02/01/2022


The Hawk's Nest makes this a 3-Story structure.
See Document Markups
Carried Forward
02/01/2022


Provide details of item in center of room and room use(s).
See Document Markups
Carried Forward
02/01/2022


A COMPLETE SET OF PLANS SUITABLE FOR REVIEW, SHOULD INCLUDE: Building Sections and Details. Architectural building sections and details shall include the following information:Foundation details. (tie-downs)Existing and proposed grade to include relationship between finished floor elevation and existing grade. Existing and finish grade at foundation for each elevation. Interior wall and ceiling finishes. (drywall, paneling, etc.)Exterior wall finishes. Exterior walls shall provide the building with a waterproof foundation or weather resistant exterior wall envelopewhere applicable. Routt County inspectors report non-compliant backfilling above masonry weepholes against woodframing. Masonry veneer shall be installed in accordance with applicable wall covering, sealant, flashing andweepholes, water-resistive barrier, metal ties, 1-in. air space, steel lintels over all openings and specify steel lintelsto support veneer and over all openings as applicable. Adhered masonry veneer shall comply with the applicable requirements in IBC Section 1405.10.1 and Sections 6.1and 6.3 of TMS 402/ACI 530/ASCE 5. RCRBD finds these requirements to be similar to cement plaster (stucco)applied to exterior walls and shall conform to similar requirements specified in Chapter 25. Commentary FigureR703.6 (3) (see attached) illustrates a similar drainage system to include a weep screed at the bottom of exteriorwalls to permit the moisture to escape to the exterior of the building. Provide details for locations of vapor retarders,include a continuous weep screed at the bottom of cultured stone (similar to stucco walls) to permit the moisture toescape to the exterior of the building. Also include specification of moisture barrier, as applicable to veneer used. Roofing details. (underlayments and roof covering materials)Stairway construction details (material specifications, handrails) Guardrail construction details. (material specifications, guardrail height, spacing of intermediate rails)
See Document Markups
Carried Forward
02/01/2022


Eliminate all gaps in insulation or trade using COMcheck.

Fees

Paid Fees Amount Paid Owing Date Paid
Routt County Planning Dept Plan Review Fee $75.00 $75.00 Paid 08/30/2021
Plan Review Fee $9,835.62 $9,835.62 Paid 08/30/2021
Building Permit Fee $15,131.73 $15,131.73 Paid 02/22/2022
Routt County Use Tax Fee $23,224.00 $23,224.00 Paid 02/22/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection Pending
Foundation Drain Inspection Pending
Silas Ebbert ((970) 870-5347)   Send Email
Insulation Inspection Pending
Grading Inspection Pending
Mike Mordi   Send Email
Final Grading Inspection Pending
Tony Brown ((970) 870-5344)   Send Email
Foundation Inspection Pending
Foundation Water Proofing Pending
Foundation/Underslab Insulation Pending
Wall/Roof Sheeting Pending
Roofing Inspection Pending
Radon Piping Pending
Shower Pan Inspection Pending
Drywall Inspection Pending
Building Final Inspection Pending
Structural Inspection Pending
Lath/Veneer Inspection Pending
Framing Inspection Pending
Miscellaneous
Outstanding
04/29/2024
1. Get engineers approval for (2)2x12 rafters instead of LVL in storage loft in "Hawks Nest" and fastening pattern 2. Get engineers approval for entryway rafters interlocked at ridge instead of 2x12 ridge beam and hangers

Foundation Inspection Partial Pass 4/5/2022 4/5/2022 04/05/2022
Silas Ebbert ((970) 870-5347)   Send Email
Foundation Inspection Partial Pass 4/8/2022 (AM) 4/11/2022 04/11/2022
Ron Norton ((970) 870-5331)   Send Email
Foundation Inspection Partial Pass 6/3/2022 6/6/2022 06/06/2022
Silas Ebbert ((970) 870-5347)   Send Email
Foundation Inspection Partial Pass 7/1/2022 7/5/2022 07/05/2022
Silas Ebbert ((970) 870-5347)   Send Email
Framing Inspection Partial Pass 8/1/2023 8/2/2023 08/02/2023
Silas Ebbert ((970) 870-5347)   Send Email
Lath/Veneer Inspection Partial Pass 8/1/2023 8/2/2023 08/02/2023
Silas Ebbert ((970) 870-5347)   Send Email
Framing Inspection Partial Pass 11/9/2023 11/9/2023 11/09/2023
Silas Ebbert ((970) 870-5347)   Send Email
Framing Inspection Partial Pass 4/29/2024 4/29/2024 04/29/2024
Silas Ebbert ((970) 870-5347)   Send Email
Miscellaneous
Carried Forward
04/29/2024
1. Get engineers approval for (2)2x12 rafters instead of LVL in storage loft in "Hawks Nest" and fastening pattern 2. Get engineers approval for entryway rafters interlocked at ridge instead of 2x12 ridge beam and hangers

Conditions

Condition Status Department Category Expiration Date Due Date
Miscellaneous Open Environmental Health Prior to Issuance of CO/CC
: NWCC should submit as-builts that reflect any changes from original plans and ensure that the installed systems are properly sized for the use in order for this office to approve for a C.O.
Miscellaneous Resolved Building Services Prior to Rough Building Wall Inspections
: F/O conditions approval approval until document mark-ups are answered.
Miscellaneous Resolved Planning and Land Use Prior to Rough Building Wall Inspections
: Record Final PUD Update: PUD recorded at Reception #837644 on 5/23/2022

Related Permit & Planning Applications

Reference Number Status Type
PRMH220860 Permit(s) Issued Mechanical
PREL231046 Permit(s) Issued Electrical
PRGS231675 Permit(s) Issued Gas

Documents & Images

Date Uploaded File Type Name
08/30/2021 20-11733 Home Ranch S&FI Report
09/29/2021 Plans OWTS Design (Received)
07/20/2023 Plans OS-1-0 (Received) (Stamped)
08/30/2021 Receipt Receipt for transaction:2021-000088
08/30/2021 Sealed Letter
09/29/2021 Letter Permit Review Corrections Notice (Generate/Send Correction Notice)
02/15/2022 Cover-Project Info_FDN ONLY (Stamped)
02/02/2022 Plans 1-18-21 PL20210022 Amd to PUD Home Ranch Final
02/22/2022 Permit Permit - Detailed (Generate/Issue Permit(s) - Building)
04/05/2022 Report Inspection Report (Foundation Inspection)
04/11/2022 Report Inspection Report (Foundation Inspection)
06/06/2022 Report Inspection Report (Foundation Inspection)
07/05/2022 Report Inspection Report (Foundation Inspection)
06/13/2023 Report ACTIONHOMERANCH-HOMERANCH_ACTION - Reports
06/13/2023 2022-11-4_Comment Response (Stamped)
06/19/2023 Letter Permit Review Corrections Notice
06/21/2023 A-E Signed Letter_HR-Lodge
06/21/2023 Boiler Spec_Trinity-Tft201
06/21/2023 Fenestration Report (1of2)
06/21/2023 Fenestration Report (2of2)
07/19/2023 20-11733 Home Ranch Lodge Pier-Pile Reports (Stamped)
07/19/2023 Home Ranch Piers-Helicals-Model (Stamped)
07/20/2023 Plans Architectural combined (Stamped)
07/20/2023 Plans Civil combined (Stamped)
07/20/2023 Plans Structural combined (Stamped)
07/20/2023 Permit Permit - Detailed (Generate/Issue Permit(s) - Building)
08/02/2023 Report Inspection Report (Framing Inspection)
08/02/2023 Report Inspection Report (Lath/Veneer Inspection)
11/09/2023 Report Inspection Report (Framing Inspection)
04/29/2024 Report Inspection Report (Framing Inspection)
04/29/2024 Report Inspection Report (Framing Inspection)