Permit Application Status
PRPF231764
You will only be able to schedule inspections if you are a contact on the permit application.
Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.
Summary
Property Owner's Full Name:
Locations
Submittals
1 Permit Application Submittal 12/27/2023
Status: Returned for Correction
Documents Returned For Corrections
Review Type
Outcome
Est. Completion Date
Completed
Fire Code Review
Approved
02/23/2024
02/29/2024
Reviewer:
Reviewer Comments:
Public Works Review
Approved
02/23/2024
02/29/2024
Reviewer:
Reviewer Comments:
External Agencies Review
Approved
02/23/2024
02/23/2024
Reviewer:
Reviewer Comments:
Electrical Review
Approved
02/23/2024
02/23/2024
Reviewer:
Reviewer Comments:
final approval subject to field inspection
Building Code Review
Failed
02/23/2024
02/16/2024
Reviewer:
Corrections:
Correction 1:
Miscellaneous
Comments:
Based on description of work, a Foundation Only Permit when issued by Routt County Regional Building Department allows the owner/contractor to proceed with the construction project at their own risk approved pending receipt of our Foundation Only Policy signed.
Following is a list of items, found during a cursory review that will need to be addressed prior to re-submitting the plans for resubmitting for Building Permit review. Please be aware that this is not a complete plan review. These items and any subsequent review questions will need to be addressed prior to the Building Permit being issued:
In review of this application, please note there are certain structure specific information that shall be provided from the manufacturer to validate certain elements for which shall be in accordance with the Routt County Regional Building Department (RCRBD) requirements as per CODE OF COLORADO REGULATIONS 8CCR 1302-14 Department of Local Affairs – Division of Housing:
1. RCRBD has adopted the 2018 “Wildfire Risk” means local building codes applied to meet the intent of the International Wildland-Urban Interface Code per Chapter 5 – Special Building Construction Regulations and shall have at least a roof assembly that complies with not less than a Class B rating when tested in accordance with ASTM E 108 or UL 790 as the materials do not appear on the list of approved noncombustible roof covering per 2018 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE Section 505.2.
2. The structural standards submitted for the containers shall match the structural design notes on plan sheet S1 to correctly specify ground and roof snow loads, wind design, and seismic data in accordance with approved RCRBD requirements.
3. While the structural calculations submitted indicates anchor types and diameter for lid embeds at container legs, RCRBD inspectors will need the plans to specify fastening design data such as field weld size(s) and length, or post installed bolt alternate as applicable.
Reviewer Comments:
Environmental Health Review
Approved
02/23/2024
02/16/2024
Reviewer:
Reviewer Comments:
No comment per Scott Cowman
GIS Land Development Review
VOID
02/23/2024
01/05/2024
Reviewer:
Reviewer Comments:
No addressing needed
Planning Review
Failed
02/23/2024
01/04/2024
Reviewer:
Reviewer Comments:
Planning cannot review this building permit until project PL20230102 (a variance to setbacks) is approved by the Board of Adjustment. The variance project is being applied for by the Environmental Health Department and is under review, but no BOA date has been scheduled yet.
2 Permit Application Submittal 03/01/2024
Status: Pending
Review Type
Outcome
Est. Completion Date
Completed
Building Code Review
Approved
10/17/2024
10/10/2024
Reviewer:
Reviewer Comments:
Updated drawings with narrative uploaded 10/09/2025 Approved [Ted Allen @ 10/10/2024 11:50 AM]
Planning Review
Approved
05/17/2024
05/13/2024
Reviewer:
Reviewer Comments:
SUP and Variance have both been issued, so Planning can approve for full construction.
Building Code Review
Approved
05/17/2024
05/13/2024
Reviewer:
Corrections:
Correction 1:
Miscellaneous
Comments:
Based on description of work, a Foundation Only Permit when issued by Routt County Regional Building Department allows the owner/contractor to proceed with the construction project at their own risk approved pending receipt of our Foundation Only Policy signed.
Following is a list of items, found during a cursory review that will need to be addressed prior to re-submitting the plans for resubmitting for Building Permit review. Please be aware that this is not a complete plan review. These items and any subsequent review questions will need to be addressed prior to the Building Permit being issued:
In review of this application, please note there are certain structure specific information that shall be provided from the manufacturer to validate certain elements for which shall be in accordance with the Routt County Regional Building Department (RCRBD) requirements as per CODE OF COLORADO REGULATIONS 8CCR 1302-14 Department of Local Affairs – Division of Housing:
1. RCRBD has adopted the 2018 “Wildfire Risk” means local building codes applied to meet the intent of the International Wildland-Urban Interface Code per Chapter 5 – Special Building Construction Regulations and shall have at least a roof assembly that complies with not less than a Class B rating when tested in accordance with ASTM E 108 or UL 790 as the materials do not appear on the list of approved noncombustible roof covering per 2018 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE Section 505.2.
2. The structural standards submitted for the containers shall match the structural design notes on plan sheet S1 to correctly specify ground and roof snow loads, wind design, and seismic data in accordance with approved RCRBD requirements.
3. While the structural calculations submitted indicates anchor types and diameter for lid embeds at container legs, RCRBD inspectors will need the plans to specify fastening design data such as field weld size(s) and length, or post installed bolt alternate as applicable.
Reviewer Comments:
Foundation Only Permit is approved
Fees
There are no fees for this permit application, or you are not authorized to view them.
Inspections
Inspection
Outcome
Requested
Scheduled
Date Inspected
Foundation Drain Inspection
Pending
Inspector:
Foundation Water Proofing
Pending
Inspector:
Foundation/Underslab Insulation
Pending
Inspector:
Wall/Roof Sheeting
Pending
Inspector:
Radon Piping
Pending
Inspector:
Drywall Inspection
Pending
Inspector:
Final Grading Inspection
Pending
Inspector:
Tony Brown
((970) 870-5344)
Send Email
Lath/Veneer Inspection
Pending
Inspector:
Building Final Inspection
Pending
Inspector:
Framing Inspection
Pending
Inspector:
Foundation Inspection
Partial Pass
6/3/2024
06/04/2024
Inspector:
Jeff Yeiser
((970) 870-5371)
Send Email
Footing Inspection
Partial Pass
6/4/2024
6/4/2024
06/04/2024
Inspector:
Jeff Yeiser
((970) 870-5371)
Send Email
Foundation Inspection
Partial Pass
6/17/2024
6/17/2024
06/17/2024
Inspector:
Jeff Yeiser
((970) 870-5371)
Send Email
Footing Inspection
Passed
8/5/2024
8/5/2024
08/05/2024
Inspector:
Ron Norton
((970) 870-5331)
Send Email
Foundation Inspection
Passed
8/5/2024
8/5/2024
08/05/2024
Inspector:
Ron Norton
((970) 870-5331)
Send Email
Framing Inspection
Partial Pass
3/5/2025
3/5/2025
03/05/2025
Inspector:
Todd Carr
((970) 870-5330)
Send Email
Framing Inspection
Partial Pass
3/12/2025
3/11/2025
03/12/2025
Inspector:
Todd Carr
((970) 870-5330)
Send Email
Conditions
Condition
Status
Category
Final Fire Inspection Required
Resolved
Prior to Issuance of TCO/CO/CC
Building Department Conditions to be Completed
Resolved
Prior to Issuance of TCO/CO/CC
Related Permit & Planning Applications
Reference Number
Status
Type
PREL240742
Permit(s) Issued
Electrical